3. SIGNALS AND WIRING
3 - 22
3.6.3 Vertical axis freefall prevention function
The vertical axis freefall prevention function avoids machine damage by pulling up the shaft slightly the
following case.
When the servo motor is used for operating vertical axis, the servo motor electromagnetic brake and the
base circuit shut-off delay time function avoid dropping axis at forced stop. However, the functions may not
avoid dropping axis a few ȝm due to the backlash of the servo motor electromagnetic brake.
The vertical axis freefall prevention function is enabled with the following conditions.
Other than "0" is set in [Pr. PC31 Vertical axis freefall prevention compensation amount].
The servo motor speed decelerates lower than the value of zero speed by turning off EM2 (Forced stop
2) or by an alarm occurrence.
The base circuit shut-off delay time function is enabled.
When [Pr. PC31 Vertical axis freefall prevention compensation amount] is set to a value other than "0", and
when the servo motor speed decelerates lower than the value of zero speed by turning off EM2 (Forced stop
2) or by an alarm occurrence, the freefall prevention function begins to work.
(1) Timing chart
MBR
(㔚⏛ࡉ࡟࡯ࠠ
ࠗࡦ࠲ࡠ࠶ࠢ)
ON
OFF(᦭ല)
ࡌ࡯ࠬ࿁〝
(ࠨ࡯ࡏࡕ࡯࠲߳ߩ
ࠛࡀ࡞ࠡଏ⛎)
ON
OFF
㔚⏛ࡉ࡟࡯ࠠታ૞േ
ήല
᦭ല
૏⟎
⒖േ㊂
ON
OFF(᦭ല)
EM2(ᒝ೙஗ᱛ2)
ࡌ࡯ࠬㆤᢿㆃᑧᤨ㑆ࠍᔅߕ⸳ቯߒߡߊߛߐ޿ޕ([Pr.PC02])
(2) Adjustment
Set the freefall prevention compensation amount in [Pr. PC31].
While the servo motor is stopped, turn off the EM2 (Forced stop 2). Adjust the base circuit shut-off
delay time in [Pr. PC02] in accordance with the travel distance ([Pr. PC31). Adjust it considering the
freefall prevention compensation amount by checking the servo motor speed, torque ripple, etc.
EM2 (Forced stop 2)
OFF
(Enabled)
Position
Base circuit (Energy
supply to the servo
motor)
MBR (Electromagnetic
brake interlock)
A
ctual operation of
electromagnetic brake
OFF
(Enabled)
Disabled
Disabled
Travel distance
Set the base circuit shut-off delay time. ([Pr. PC02])