5. PARAMETERS
5 - 14
No. Symbol Name and function
Initial
value
(unit)
Setting
range
PA09 RSP Auto tuning response
Set a response of the auto tuning.
16 1 to 40
Machine characteristic
Setting
value
Response Guideline for machine
resonance frequency [Hz]
1 2.7
2 3.6
3 4.9
4 6.6
5 10.0
6 11.3
7 12.7
8 14.3
9 16.1
10 18.1
11 20.4
12 23.0
13 25.9
14 29.2
15 32.9
16 37.0
17 41.7
18 47.0
19 52.9
20 59.6
21 67.1
22 75.6
23 85.2
24 95.9
25 108.0
26 121.7
27 137.1
28 154.4
29 173.9
30 195.9
31 220.6
32 248.5
33 279.9
34 315.3
35 355.1
36 400.0
37 446.6
38 501.2
39 571.5
40
Low
response
Middle
response
High
response
642.7
PA10 INP In-position range
Set an in-position range per command pulse.
1600
[pulse]
0 to
65535