14. USING A LINEAR SERVO MOTOR
14 - 9
(1) Magnetic pole detection method by using MR Configurator2
The following shows the magnetic pole detection procedure by using MR Configurator2.
(a) Magnetic pole detection by the position detection method
[AL.32 ㆊ㔚ᵹ]
[AL.50 ㆊ⽶⩄1][AL.51 ㆊ⽶⩄2]
߅ࠃ߮[AL.E1 ㆊ⽶⩄⼊]
߇⊒↢
ߒߚ߆
?
1) FLS(਄㒢ࠬ࠻ࡠ࡯ࠢ࡝ࡒ࠶࠻)RLS(ਅ㒢ࠬ࠻ࡠ࡯ࠢ࡝ࡒ࠶࠻)߅ࠃ߮EM2(ᒝ೙஗ᱛ2)߇ࠝࡦ
ߦߥߞ
ߡ޿ࠆߎߣࠍ⏕⹺ߒ㧘ࠨ࡯ࡏࠕࡦࡊߩ㔚Ḯࠍ޿ߞߚ
ࠝࡈߦߒ㧘ౣᐲ㔚Ḯࠍᛩ౉ߒ߹ߔޕ
ࠨ࡯ࡏࠕࡦࡊߩ࠹ࠬ࠻
ㆇォಾ឵߃ࠬࠗ࠶࠴
(SW2-1)"ࠝࡦ()"ߦ⸳ቯߒࠨ࡯ࡏࠕࡦࡊ
ߩ㔚Ḯࠍ
޿ߞߚࠎࠝࡈߦߒ㧘ౣᐲ㔚Ḯ
ࠍᛩ౉ߒ߹ߔޕ
[Pr.PL08 ࡝࠾ࠕࠨ࡯ࡏࡕ࡯࠲/DDࡕ࡯࠲ᯏ⢻ㆬᛯ3]"_ _ _ 0"ߦ⸳ቯߒߡ⏛ᭂᬌ಴ᣇᴺ
"૏⟎ᬌ಴
ᣇᑼ"ߦߒ߹ߔ
ޕ
ࠨ࡯ࡏࠕࡦࡊߩ㔚Ḯࠍ޿ߞߚࠎࠝࡈ
ߦߒ㧘ౣᐲ㔚Ḯࠍᛩ౉ߒ߹ߔޕ
6) [Pr.PL09 ⏛ᭂᬌ಴㔚࿶
࡟ࡌ࡞
]ࠍ⋡቟
ߣߒߡ
"10"(⋡቟୯)ߦ⸳ቯߒ߹ߔ
ޕ
7) MR Configurator2ߩ࠹ࠬ࠻ㆇォ
ࡕ࡯࠼ߩ
"૏⟎᳿
߼ㆇォ
"ߢ"ᱜᣇะ⒖"߹ߚߪ"ㅒᣇะ⒖"ࠍታⴕ
ߒ߹ߔޕߎߩߣ߈
㧘⒖േ㊂ࠍ
"0"ߦߒߡߊߛߐ޿
ޕ
8)
[Pr.PL01]"_ _ _ 0"ߦ⸳ቯ
ߒߡ
"ᭂᬌ
಴ή"ߦߒ߹ߔ
ޕ
()
2)
3)
4)
5)
⏛ᭂᬌ಴߇ታᣉ
ߐࠇ߹ߔޕ
[Pr.PL09]
ߪᦨ⚳୯
߆
?
[AL.27 ೋᦼ⏛ᭂᬌ಴⇣Ᏹ]
߇⊒↢
ߒߚ߆
?
ࠕ࡜࡯ࡓ࡝࠮࠶࠻
߹ߚߪࠨ࡯ࡏ
ࠕࡦࡊߩ㔚Ḯࠍ޿ߞߚ
ࠝࡈߦ
ߒ㧘ౣᐲ㔚Ḯ
ᛩ౉ߒ߹ߔޕ
ࠨ࡯ࡏࠕࡦࡊߩ
㔚Ḯࠍ޿ߞߚࠎ
ࠝࡈߦߒ㧘ౣᐲ㔚Ḯ
ࠍᛩ౉ߒ߹
ߔ
ޕ
ࠕ࡜࡯ࡓ࡝࠮࠶࠻
߹ߚߪࠨ࡯ࡏ
ࠕࡦࡊߩ㔚Ḯࠍ޿ߞߚ
ࠝࡈߦ
ߒ㧘ౣᐲ㔚Ḯ
ᛩ౉ߒ߹ߔޕ
[Pr.PL09]ߩ୯
5਄ߍ߹ߔ
ޕ
[Pr.PL09]ߩ
70%ࠍᦨ⚳⸳ቯ
ߦߒ߹ߔ
ޕ
ߎߩ୯
ߢ㧘
[AL.27 ೋᦼ⏛ᭂᬌ಴
⇣Ᏹ]߇಴ࠆ
႐ว㧘
[AL.E1 ㆊ⽶⩄
⼊๔]߇⊒↢ߒߚ
୯ߣ
[AL.27 ೋᦼ
⏛ᭂᬌ಴⇣Ᏹ]߇⊒↢ߒߚ
୯ߩਛ
㑆ߩ୯ࠍᦨ⚳⸳ቯ
ߦߒ߹ߔޕ
NO
YES
YES
NO
YES
NO
⏛ᭂᬌ಴
⚳ੌ
[Pr.PL01 ࡝࠾ࠕࠨ࡯ࡏࡕ࡯࠲/DDࡕ࡯࠲ᯏ⢻ㆬᛯ1]"_ _ _ 1"ߦ⸳ቯ
ߒߡ
"ೋ࿁ࠨ࡯ࡏࠝ
⏛ᭂᬌ
"ߦߒ߹ߔ
ޕ
()
Note. When the linear encoder is an incremental type, the [Pr. PL01] setting is not required.
Ma
g
netic
p
ole detection
Check that FLS (Upper stroke limit), RLS (Lower stroke limit), and EM2 (Forced stop 2)
are on, and turn the servo amplifier power off and on again.
Set the test operation select switch (SW2-1) of the servo amplifier to "Up", and turn the
se
rv
o
a
m
p
lifi
e
r
po
w
e
r
o
ff
a
n
d
o
n
aga
in.
Set [Pr. PL08 Linear servo motor/DD motor function selection 3] to "_ _ _ 0" to set the
m
ag
n
e
ti
c
po
l
e
de
t
ec
ti
o
n m
e
th
od
t
o
"P
os
iti
o
n
de
t
ec
ti
o
n m
e
th
od
"
Set [Pr. PL01 Linear servo motor/DD motor function selection 1] to "_ _ _ 1" to enable
"M
ag
n
e
ti
c
po
l
e
de
t
ec
ti
o
n
a
t fir
s
t
se
rv
o
-
o
n".
Turn the servo amplifier power off and on again.
Set [Pr. PL09 Magnetic pole detection voltage level] to
"
10
"
(guide value).
Execute "Positive direction travel" or "Negative direction travel" with "Positioning operation" in the
test operation mode on MR Configurator2. Set the travel distance to "0" at this time.
The ma
g
netic
p
ole detection is carried out.
Is [Pr. PL09] the
final value?
Has [AL. 27 Initial magnetic
p
ole detection error
]
occurred?
Set [Pr. PL01] to "_ _ _ 0" to set "Magnetic pole detection invalid". (Note)
Reset the alarm or turn off the
servo amplifier power, and
then turn on the power again.
Turn the servo amplifie
r
power off and on again.
Reset the alarm or turn off the
servo amplifier power, and then
turn on the power again.
Increase the value of [Pr. PL09] by five.
Set an approximately 70% of the value set
for [Pr. PL09] as the final setting value.
If [AL. 27 Initial magnetic pole detection
error] occurs with this value, specify a
value intermediate between the value set
at [AL. E1 Overload warning 1] and the
value set at [AL. 27 Initial magnetic pole
detection error] as the final setting value.
End
Have [AL. 32 Overcurrent], [AL. 50
Overload 1], [AL. 51 Overload 2], and
[
AL. E1 Overload warnin
g
1
]
occurred?
disabled".
(
Note
)
Page view 295