5. PARAMETERS
5 - 24
No. Symbol Name and function
Initial
value
(unit)
Setting
range
PB17 NHF
Table 5.4 Shaft resonance suppression filter setting
frequency selection
Refer to Name
and function
column.
Setting
value
Frequency [Hz]
Setting
value
Frequency [Hz]
00 Disabled 10 562
01 Disabled 11 529
02 4500 12 500
03 3000 13 473
04 2250 14 450
05 1800 15 428
06 1500 16 409
07 1285 17 391
08 1125 18 375
09 1000 19 360
0A 900 1A 346
0B 818 1B 333
0C 750 1C 321
0D 692 1D 310
0E 642 1E 300
0F 600 1F 290
PB18 LPF Low-pass filter setting
Set the low-pass filter.
The following shows a relation of a required parameter to this parameter.
3141
[rad/s]
100 to
18000
[Pr. PB23] [Pr. PB18]
_ _ 0 _ (Initial
value)
Automatic setting
_ _ 1 _ Setting value
enabled
_ _ 2 _ Setting value
disabled
PB19 VRF11 Vibration suppression control 1 - Vibration frequency
Set the vibration frequency for vibration suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically. Set manually for "Manual setting (_ _ _ 2)".
Refer to section 7.1.5 for details.
100.0
[Hz]
0.1 to
300.0
PB20 VRF12 Vibration suppression control 1 - Resonance frequency
Set the resonance frequency for vibration suppression control 1 to suppress low-frequency
machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically. Set manually for "Manual setting (_ _ _ 2)".
Refer to section 7.1.5 for details.
100.0
[Hz]
0.1 to
300.0
PB21 VRF13 Vibration suppression control 1 - Vibration frequency damping
Set a damping of the vibration frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically. Set manually for "Manual setting (_ _ _ 2)".
Refer to section 7.1.5 for details.
0.00 0.00 to
0.30
PB22 VRF14 Vibration suppression control 1 - Resonance frequency damping
Set a damping of the resonance frequency for vibration suppression control 1 to suppress low-
frequency machine vibration.
When "Vibration suppression control 1 tuning mode selection" is "Automatic setting (_ _ _ 1)" in
[Pr. PB02], this parameter will be set automatically. Set manually for "Manual setting (_ _ _ 2)".
Refer to section 7.1.5 for details.
0.00 0.00 to
0.30