Sharp CP-SR421 User Manual Page 145

  • Download
  • Add to my manuals
  • Print
  • Page
    / 404
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 144
5. PARAMETERS
5 - 48
No. Symbol Name and function
Initial
value
(unit)
Setting
range
PL17 LTSTS
Table 5.10 Load to motor mass ratio/load to motor inertia ratio
Setting value
Load to motor mass
ratio/load to motor
inertia ratio
Setting value
Load to motor mass
ratio/load to motor
inertia ratio
Refer to Name
and function
column.
0 10 times or less 8 80 times
1 10 times 9 90 times
2 20 times A 100 times
3 30 times B 110 times
4 40 times C 120 times
5 50 times D 130 times
6 60 times E 140 times
7 70 times F 150 times or more
PL18 IDLV Magnetic pole detection - Minute position detection method - Identification signal amplitude
Set an identification signal amplitude used in the minute position detection method.
This parameter is enabled only when the magnetic pole detection is the minute position
detection method.
However, setting "0" will be 100% amplitude.
0
[%]
0 to
100
Page view 144
1 2 ... 140 141 142 143 144 145 146 147 148 149 150 ... 403 404

Comments to this Manuals

No comments