3. SIGNALS AND WIRING
3 - 13
3.3.3 Wiring CNP1, CNP2, and CNP3
POINT
For the sizes of wires used for wiring, refer to section 11.11.
MR-J3-500B or more do not have these connectors.
Use the servo amplifier power supply connector for wiring CNP1, CNP2 and CNP3.
(1) Connectors
(a) MR-J4-10B to MR-J4-100B
CNP2
CNP1
CNP3
Servo amplifier
Table 3.1 Connector and applicable cable
Applicable cable
Connector Receptacle assembly
Size Insulator OD
Stripped
length [mm]
Open tool
Manufa
cturer
CNP1 06JFAT-SAXGDK-H7.5
CNP2 05JFAT-SAXGDK-H5.0
CNP3 03JFAT-SAXGDK-H7.5
AWG 18 to 14 3.9 mm or less 9 mm J-FAT-OT JST
(b) MR-J4-200B/MR-J4-350B
CNP2
CNP1
CNP3
MR-J4-200B
Servo amplifier
CNP2
CNP1
CNP3
MR-J4-350B
Servo amplifier
Table 3.2 Connector and applicable cable
Applicable cable
Connector Receptacle assembly
Size Insulator OD
Stripped
length [mm]
Open tool
Manufa
cturer
CNP1 06JFAT-SAXGFK-XL
CNP3 03JFAT-SAXGFK-XL
AWG 16 to 10 4.7 mm or less 11.5 mm
CNP2 05JFAT-SAXGDK-H5.0 AWG 18 to 14 3.9 mm or less 9 mm
J-FAT-OT-EXL JST
CNP3
CNP2