Sharp FO-6700 Service Manual Page 39

  • Download
  • Add to my manuals
  • Print
  • Page
    / 192
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 38
FO-6700U
FO-67DL
SW45 No. 5 ~ No. 8 CI signal off detect enable time
Used to set the continuous detection time during OFF period of CI sig-
nal. Normally set to 700ms, where the short ring (500ms: OFF period)
cannot be detected. Therefore, selection of 350ms is allowed.
SW46 No. 1 ~ No. 4 Reserved
Set to "0".
SW46 No. 5 ~ No. 8 Distinctive ringing
When the ringing setting is turned off, all of the CI signal are received.
When any of the standard, and ring patterns 1 through 3 is selected for
the ringing setting, only the selected CI signal is received.
CI signal patterns
The CI signal patterns consists of the standard pattern, and ring pat-
terns 1 through 7. The standard pattern is the conventional one.
SW39 No. 6 ~ No. 8 Reserved
Set to "0".
SW40 No. 1 Reserved
Set to "1".
SW40 No. 2 Reserved
Set to "0".
SW40 No. 3 Reserved
Set to "1".
SW40 No. 4 ~ No. 6 Reserved
Set to "0".
SW40 No. 7 Reserved
Set to "1".
SW40 No. 8 Reserved
Set to "0".
SW41 No. 1 ~ No. 4 V.34 mode transmission speed
Used to determine the initial modem speed when communication method
is V.34 transmission mode.
SW41 No. 5 ~ No. 8 V.34 mode receiving speed
Used to determine the initial modem speed when communication method
is V.34 reception mode.
SW42 No. 1 Reserved
Set to "1".
SW42 No. 2 V.34 mode function
Used to select the V.34 mode for communication when set to “1”, com-
munication method is V.34 mode..
SW42 No. 3 V.34 control channel communication speed
Used to select the control channel communication speed for V.34 mode.
SW42 No. 4, No. 5 EOL detection timer
Used to make a choice of whether to use the 25-second or 13-second
timer for detection of End of line This is effective to override communica-
tion failures with some facsimile models that have longer End of line
detection.
SW42 No. 6, No. 7 Processing of DIS reception after DIS trans-
mission
When receiving , operation in case of DIS reception after DIS transmis-
sion is selected. Retransmitting command: To retransmit DIS in disre-
gard of DIS reception.
Breaking circuit: To break circuit instantly. (Abnormal finish)
T. 30: To operate in accordance with T.30.
T. 30+α: To operate in accordance with T.30+α. (To operate differently
according to cases.)
SW42 No. 8 The change to DB from DP by
When setting to 1, the mode is changed by pressing the key from the
pulse dial mode to the tone dial mode.
SW43 No. 1 ~ No. 5 DTMF output level (High)
To set the level to output high group DTMF signals. –15 to 0 dBm (0.5
dBm unit)
SW43 No. 6 ~ No. 8 Reserved
Set to "0".
SW44 No. 1 ~ No. 5 DTMF output level (Low)
To set the level to output low group DTMF signals. –15 to 0 dBm (0.5
dBm unit)
SW44 No. 6 ~ No. 8 Reserved
Set to "0".
SW45 No. 1 ~ No. 4 Frequency of CI signal
Used to set the detection frequency of CI signal.
2 – 31
2S
4S
1.5S
3S
1S
4S
1.5S
4S
0.8S
4S
0.3S
4S
0.4S
4S
1S
3.5S
0.5S
3S
0.5S
3S
2S
2S
0.5S
0.5S
1S
0.2S
0.8S
0.4S
0.3S
0.2S
0.4S 0.8S
0.2S 0.2S
1S
0.5S
1S 0.5S
0.5S0.5S
0.5S
1S
0.5S0.5S
STANDARD
RING
PATTERN 1
for USA
RING
PATTERN 2
for USA
RING
PATTERN 3
for USA
RING
PATTERN 1
for CANADA
RING
PATTERN 2
for CANADA
RING
PATTERN 3
for CANADA
1S
3S
1S
RING
PATTERN 4
for USA
1S
SW47 No. 1 ~ No. 7 Reserved
Set to "0".
SW47 No. 8 Reserved
Set to "1".
SW48 No. 1 Reserved
Set to "1".
SW48 No. 2 ~ No. 4 Reserved
Set to "0".
SW48 No. 5, No. 6 Reserved
Set to "1".
SW48 No. 7, No. 8 Reserved
Set to "0".
SW49 No. 1 Reserved
Set to "1".
SW49 No. 2 ~ No. 4 Reserved
Set to "0".
Page view 38
1 2 ... 34 35 36 37 38 39 40 41 42 43 44 ... 191 192