1 Memory retransmission times Binary input 8421 1 OPTION
2 No. = 1234(Data No.) 0
3 EX 1010 1
SW10
4 eg. Retransmission time set to 10 times. 0
5 Memory retransmission interval Binary input 8421 0 OPTION
6 No. = 5678(Data No.) 0
7 EX 0010 1
8 0
1 V.34 mode transmission speed Sending speed = 2400 (bps) x N 1
2 Example : 1
3 2400 (bps) x 12 = 28800 (bps) 1
4 2400 (bps) is set for N=0. 33600 (bps) is set for N=15. 0
SW11
5 V.34 mode receiving speed Receiving speed = 2400 (bps) x N 1
6 Example : 1
7 2400 (bps) x 12 = 28800 (bps) 1
8 2400 (bps) is set for N=0. 33600 (bps) is set for N=15. 0
1
V.34 mode function in case of manual communication
On Off 1
2 V.34 mode function On Off 1
3 V.34 control channel communication speed 2400bps 1200bps 0
EOL detection timer 13sec 25sec 5sec 5sec
4 No. 4 0 0 1 1 0
SW12
5 No. 5 0 1 0 1 0
Processing of DIS reception after DIS
Retransmitting
A line is Apply to T.30+α
transmission
command
cut T.30
6 No. 6 0 0 1 1 0
7 No. 7 0 1 0 1 0
8 The change to DB from DP by Yes No 0
1 DTMF output level (High) Binary input 16 8 4 2 1 0
2 No. = 12345 (Data No.) n x 0.5dBm 1
3 EX 01100 1
4 eg. Signal transmission level is set to -10dBm 0
SW13
5 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
1 DTMF output level (Low) Binary input 16 8 4 2 1 1
2 No. = 12345 (Data No.) n x 0.5dBm 0
3 EX 10000 0
4 eg. Signal transmission level is set to -10dBm 0
SW14
5 0
6 Reserved 0
7 Reserved 0
8 Reserved 0
SW
NO.
DATA
NO.
ITEM
Switch setting and function
Remarks
Initial
setting
1
0
2 – 12
Page view 19