FO-6700U
FO-67DL
The cursor blinks at the top data.
Three counters can be selected with the "#" and " " keys.
In the state , input a desired setting number of 6 digits with the ten-
key.
After input of 6 digits, shift to another counter with the "#" and " "
keys as necessary. When all necessary counters are completely in-
put, press the START key.
"STORED" will be displayed with the set values stored into the
memory. For checking, retry this mode.
Note: The counter shows the operational state of the printer (how many
sheets have been printed since start of use? and others). The
ordinary memory does not reset the counter. Accordingly, it is
necessary to reset the counter or do the clear process in addi-
tion to the ordinary memory clear if the content in the memory
on the control PWB is broken because of PWB repair, etc. (In
the production stage, it is necessary to execute this in the last
process.)
Rapid key 10: Top adjust mode
As the method to adjust the top margin for printing, adjust top margin
adjusting VR on the PWB. If this mode is used at this time, adjustment is
possible without the printing test every time when VR is turned.
For the practical use, determine the adjusting value on the basis of the
old data, and adjust to the determined value in this mode. Then, check it
with the printing test.
Rapid key 11: Life clear mode
The mode is used to respectively clear the life counter of the printer and
the counter of the auto feeder. For setting, proceed with the following
procedure.
When the life counter clearing mode is selected, the following will be
is displayed.
Seven counters can be selected with the "#" and " " keys.
In the state , input the CLEAR key, and the counter will be respec-
tively cleared.
After one clear, move the cursor to another counter with the "#" and
" " keys as necessary, and then press the CLEAR key. When the
necessary counters are completely cleared, press the STOP key.
MACHINE
DRUM
L
LIFE
LIFE
IFE1
LEAR
FEEDER L I FE LEAR
TONER L I FE LEAR
LEAR
LEAR
LIFE2
LEAR
LIFE3
LEAR
C
C
C
C
C
C
C
key
# key
Note:
This counter indicates the printer use conditions such as numbers of
printed pages from the beginning of use. In the normal memory clear
condition, the counter will not be reset.
In conditions including damaged memory contents caused by repairing
the panel, this counter should be reset or cleared in addition to the ordi-
nary memory clear.
Operation Manual for multipurpose Counter Life 1-3
The FAST function of LIFE 1-3 automatically notifies the dealer that the
printer life has reached the optional judgement value. This function can
be applied to notify when the life of consumables such as the printing
unit and fixer is expired.
How to use it
(1) Set the optional judgement value (counter value for alarming) of the
multipurpose life counter 1-3 in the printer diagnotor 09: LIFE ENTRY
MODE.
The setting procedure is as follows:
1. Select each counter with " " or "#" key. (Refer to the chart below.)
2. Enter 6 digits using the ten key on the screen of the judgement
value to be set.
3. If another value is to be set after completion of the first entry,
move onto another value with "#" or " " key and enter digits in
the same procedure. Press the "START" key when all values are
entered. (Writing is completed when "STORED" appears on the
display.)
(2) The counter whose value is set in (1) will start counting every time a
letter is printed.
(3) When each counter reaches its judgement value, the FAST auto
matic notification function is activated and alarms it to the dealer.
If the FAST function is off, the counter only counts and does not notify
the dealer automatically.
Rapid key 08: Life all clear
The mode is used to clear the life counter of the printer of the counter
of the auto feeder.
Note: The counter shows the operational state of the printer (e.g. how
many sheets have been printed since start of use?). The ordi-
nary memory does not reset the counter. Accordingly, it is nec-
essary to reset this counter in addition to the ordinary memory
clear if the content in the memory on the control PWB is broken
because of PWB repair, etc. (In the production stage, it is nec-
essary to execute this in the last process.)
Rapid key 09: Life entry mode
(For Serviceman temporary counter)
The mode is used to set a desired value for the judgment value (alarm
judgment counter value) of the general purpose life counters 1 thru 3 of
the printer. If the life of a consumable part (developer, imprinter, etc) is
set, the model which has the error display and RMS function will inform
RMS when the counter reaches the set value. For setting, proceed with
the following procedure.
When the life counter setting mode is selected, the following will be
displayed.
LI FE1= 00000
LI FE2= 00000
LI FE3= 00000
0
0
0
# key
key
2 – 8
LI FE1= 00000
LI FE2= 00000
LI FE3= 00000
0
0
0
# key
key
Page view 15