User service screws
1
2
4 Remove the lamp unit.
Loosen the securing screws from the
lamp unit. Hold the lamp unit by the
handle and pull it in the direction of
the arrow.
5 Insert the new lamp unit.
Press the lamp unit firmly into the lamp
unit compartment. Fasten the secur-
ing screws.
6 Attach the lamp unit cover.
Close the lamp unit cover in the direc-
tion of the arrow (to the close mark)
on the side of the projector. Then
tighten the user service screws.
Info
If the lamp unit and lamp cover are not
correctly installed, the power will not turn
on, even if the power cord is connected
to the projector.
Resetting the Lamp Timer
Reset the lamp timer after replacing the lamp.
1 Connect the power cord.
Plug the power cord into the AC socket
of the projector.
2 Reset the lamp timer.
While holding down , " and | on
the projector, press
on the projector.
LAMP 0000H is displayed, indicat-
ing that the lamp timer is reset.
Info
Make sure to reset the lamp timer only
when replacing the lamp. If you reset the
lamp timer and continue to use the same
lamp, this may cause the lamp to become
damaged or explode.