➥ Change any worn or deformed components
❒
Check the grate drive for dirt and deposits
9 Air-cooled grate side plates
❒
Check the grate side plates for dirt and slag and clean the openings with a slotted
screwdriver if necessary
Quarterly
10 Flue gas sensor
❒ Loosen the retaining screw and pull out the flue gas sensor
❒ Wipe off the flue gas sensor with a clean cloth
❒ Insert the flue gas sensor back into the flue gas pipe and finger-tighten the retain‐
ing screw