7 Combustion chamber
Using the flat scraper, pull the ash on the combustion chamber grate out through
the cleaning port door
Carefully remove deposits on side walls using the flat scraper and cleaning brush
CAUTION! Be careful not to damage the firebricks with the flat scraper or
cleaning brush.
Shovel ash from the chamber into a fire-resistant container with a lid
Check the burn-through rings
Systems with automatic ash removal:
After cleaning the boiler switch on the main switch on the switch cabinet
Once the controller has initialised, switch on the ash removal screws in the "Test
operation" menu to transfer the ash to the ash container
The ash removal screws of the heat exchanger ash removal system will also
operate at the same time.
Empty ash container if necessary
8 Conveyor grate
Check the conveyor grate for dirt and obstructions (nails, stones, slag,...). Clean
where necessary
The primary air slots (wood chip grate) or primary air holes (pellet grate) must
be free and unobstructed
Check the grate, grate shafts and grate bearings for wear and deformation
Servicing
4
Maintenance schedule