Monthly
7 Combustion chamber
❒
Using the flat scraper, pull the ash on the combustion chamber grate out through
the cleaning port door
❒ Carefully remove deposits on side walls using the flat scraper and cleaning brush
➥ CAUTION! Be careful not to damage the firebricks with the flat scraper or
cleaning brush.
❒ Shovel ash from the chamber into a fire-resistant container with a lid
❒ Check the burn-through rings
Systems with automatic ash removal:
❒ After cleaning the boiler switch on the main switch on the switch cabinet
❒ Once the controller has initialised, switch on the ash removal screws in the "Test
operation" menu to transfer the ash to the ash container
➥ The ash removal screws of the heat exchanger ash removal system will also
operate at the same time.
❒ Empty ash container if necessary
8 Conveyor grate
❒
Check the conveyor grate for dirt and obstructions (nails, stones, slag,...). Clean
where necessary
➥ The primary air slots (wood chip grate) or primary air holes (pellet grate) must
be free and unobstructed
❒ Check the grate, grate shafts and grate bearings for wear and deformation
Servicing