2.7 Residual risks
WARNING
When touching hot surfaces:
Severe burns are possible on hot surfaces and the flue gas pipe!
When work is carried out on the boiler:
Shut down the boiler in a controlled way (operating status "Switched off Off")
and allow it to cool down
Protective gloves must generally be worn for work on the boiler, and it should
only be operated using the handles provided
Insulate the flue pipes or simply avoid touching them during operation.
WARNING
If the combustion chamber, cleaning port, reversing chamber or middle vault door
is opened during operation:
Opening a door may result in injury or damage or flue gas generation!
Take the following precautions:
Do not open the doors while the boiler is operating!
WARNING
If non-permitted fuel types are used:
Non-standard fuels can cause serious faults in combustion (e.g. spontaneous
combustion of carbonisation gases / flash fires) which can lead to serious acci‐
dents!
Take the following precautions:
Only use fuels specified in the "Permitted fuels" section of these operating in‐
structions.
2
Safety
Residual risks
18 Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com