Check the grate area and ash rakes for dirt and deposits. Clean where necessary
➥ Check the seal when replacing the cleaning cover
Six-monthly
13 Flue gas pipe (option)
❒
Remove the pipe insulation from the inspection cover
❒ Unfasten the nuts on the inspection cover and remove the cover
❒ Check the pipe for dirt and deposits. Clean where necessary
14 Actuators, drives
❒
Visually check the function of the drives of the feed and ash removal screws and
the grate
Check the efficiency of the air flap actuators:
❒ Press the reset button on the servo motor to release the air flap
➥ Hold down the reset button
❒ Turn the air flap to the left-hand stop
❒ Release the reset button
➥ The air flap must return automatically to its original position (only if the main
switch is switched on)
4
Servicing
Maintenance schedule
34 Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com