Sharp R-426H Service Manual Page 89

  • Download
  • Add to my manuals
  • Print
  • Page
    / 194
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 88
1. Specifications
1
2
3
4
5
I - 103
1-11 Installation Instructions
Selecting the Installation Site
Wind Shield
It is recommended to install wind shields for cooling
operation in low outdoor temperature condition.
(Fig. 1-10)
General
When the outdoor unit is installed in a position ex-
posed to strong wind (like seasonal winds with low air
temperature in winter), wind shield must be installed
on the outdoor unit.
This unit is designed so that the fan of the outdoor unit
runs at low speed when the air conditioner is operated
at low outdoor air temperatures. When the outdoor unit
is exposed to strong wind, the system pressure drops
because of the freeze protector.
For outer dimensions of wind shield, please see
Fig. 1-11.
Important
Fig. 1-10
Wind shield
(air discharge side)
Front
0935_C_I
1546_C_I
3 - ø40 hole
6 - ø6 hole
25054924
132
57013
596
554
13125025027
554
1545_C_I
3 - ø60 hole
8 - ø6 hole
450 100250250
1116
132
567
131
300
592
For 25 typeFor 36, 48 type
Recommended outer dimensions of wind shield
(field supply)