1. Specifications
1
12
3
4
5
I-48
1-2 Major Component Specifications
(B) Outdoor Unit
MODEL No. AER 425 SCL3E
Source 380 - 400 - 415 V / 3 phase / 50 Hz
Controller P.C.B. Ass'y CR - CR483GHL8 (Microprocessor)
Control circuit fuse 250 V, 3.15 A
Compressor Rotary (Hermetic)
Model ..... number C - RN223H8D
Source 380 - 400 - 415 V / 3 phase / 50 Hz
Nominal output W 2400
Compressor oil cc 1350
Coil resistance T – R : 5.77 , R – S : 5.66
(Ambient temperature 25 °C) S – T : 5.38
Safety devices
Overload relay models Internal type
Operating temperature Open °C120± 5
Close °C98± 11
Crank case heater 240V, 25 W
Refrigerant amount at shipment kg R407C - 3.2
High pressure switch ACB
-
1TB07
Set pressure OFF kg/cm
2
32 (3.2 MPa)
ON kg/cm
2
24 ± 2.0 (2.4 ± 0.2 MPa)
Fan Propeller
Number...diameter mm 1 ..... ø460
Air circulation (Hi) m
3
/h 45
Fan speeds 3 (AUTO)
Fan motor
Model KFC6T - 91C5P
Source 220 - 230 - 240 V / 1 phase / 50 Hz
No. of pole ..... rpm (230V, High / Med. / Low) 6...772 / 376 / 252
Nominal output W 70
Coil resistance WHT BRN : 127.3 , VLT YEL : 15.0
(Ambient temperature 20°C) WHT VLT : 56.7 , YEL PNK : 7.2
Safety device Internal type
Operating temperature Open °C130± 8
Close °C79± 15
Run capacitor VAC, µF 440 V, 6 µF
Heat exchange
Coil Aluminium plate fin / Copper tube
Rows ..... fin pitch mm 2 ..... 1.8
Face area m
2
0.616
+ 0
– 1.5
+ 0
– 0.15