Sharp ER-A770 Service Manual Page 24

  • Download
  • Add to my manuals
  • Print
  • Page
    / 89
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 23
b0
An interruption of send complete cannot be made.
(DMAC TC UP interruption)
Execute diagnostics command 5. The error status is displayed.
The names and the directions of the signals which are subject
to diagnostics 5 command are as shown in the table below.
Signal name Direction
Power interruption notice Host
Controller
Power interruption ON initialization Host
Controller
Power interruption ON continuation Host
Controller
Power interruption process complete Host
Controller
CH1 reception data present. Host
Controller
CH2 reception data present. Host
Controller
Check that the target bit of two statuses obtained by diagnostics
5 command is "0" for ST1 and "1" for ST2. (The other bits must
be masked.) In the other cases, the error status is displayed with
the error occurrence bit as "1." The normal bit shows "0."
The error status from the host to the controller is as shown in the
table below.
b7 Not used. ("0" is always displayed.)
b6 Power interruption notice
b5 Not used. ("0" is always displayed.)
b4 Not used. ("0" is always displayed.)
b3 Not used. ("0" is always displayed.)
b2 Not used. ("0" is always displayed.)
b1 Power ON continuation
b0 Power ON initializing
The error status from the controller to the host is as shown in the
table below.
b7 Not used. ("0" is always displayed.)
b6 Power interruption notice
b5 Not used. ("0" is always displayed.)
b4 CH2 reception data exits.
b3 CH1 reception data exits.
b2 Power interruption process complete
b1 Not used. ("0" is always displayed.)
b0 Not used. ("0" is always displayed.)
Display
Terminating procedure
Press the CANCEL key to terminate the check. After terminating,
perform the service reset.
2) SRN Flag Send Check
Check content
Execute diagnostics 3 command to send Flag (7EH) continuously.
Display
Terminating procedure
Perform the service reset.
3) SRN Data Send Check
Check content
Execute diagnostics 4 command to send data of 00H ~ FFH
(256Byte) as one packet at 12.8msec packet interval at 1Mbps
continuously.
Display
Terminating procedure
Perform the service reset.
4) Data Transmission Check
Data transmission is checked in an actually composed system. The
system is composed of one master machine and max. 15 satellite
machines.
Note for starting the check
When checking the set in which the SRN setting has been
made, cancel the SRN setting before starting this check.
When checking the actually composed system, disconnect the
SRM cables of the sets which are not checked, or cancel the
SRN setting. If it is set to "SRN exits," data may be destroyed.
The transmission check setting must be performed after can-
celing the SRN setting of all the sets in the system. First, set
the satellite machines, then set the master machine.
Setting procedure
Satellite machine setting
In the menu screen, select "Data Transmission Check (Satel-
lite)."
The display is as follows:
Enter the terminal No. (000 ~ 254, 3 digits) of the machine to be
checked and press the ENTER key. The display is as shown
below.
SRN Self Check
DATA RETRY CNT.=xxx
ACK RETRY CNT.=xxx
DIAG 0
:xxxxxxxx
DIAG 1 :xxxxxxxx
DIAG 5 H
C :xxxxxxxx
DIAG 5 H
C :xxxxxxxx
The number of resending is displayed
in xxx with a decimal number.
In the sequence of b7, b6, ..., b0 from
the left. "1" is displayed in case of an
error, and "0" when normal.
In the sequence of b7, b6, ..., b0 from
the left. "1" is displayed in case of an
error, and "0" when normal.
In the sequence of b7, b6, ..., b0 from
the left. "1" is displayed in case of an
error, and "0" when normal.
In the sequence of b7, b6, ..., b0 from
the left. "1" is displayed in case of an
error, and "0" when normal.
SRN Flag Send Check
SRN Data Send Check
Data Transmission Check (Satellite)
Input Terminal Number :
Data Transmission Check (Satellite)
Input Terminal Number : xxx
Data Sequence Number : 0000
The entered
terminal No.
is displayed.
Page view 23