Programming alarm length of time with drawer opening
If the drawer still remains open when a specified length of time has elapsed, your machine gives the alarm.
Your machine starts to monitor how long the drawer is kept open the moment the drawer is opened
at the end of a transaction in the REG/VOID mode. It stops the time monitoring when a valid key
(except the
Ú
and
q
keys) is pressed for the next transaction. It restarts the time monitoring
after that transaction is ended. You can stop the buzzer alarm by closing the drawer. No key entries
can be made while the buzzer is sounding.
Programming of validation printing, slip printing, and difference subtotal
printing
* AB: Initial line feed for a slip (0 64 lines)
CD: Maximum number of lines printable on a slip (0 99)
E: Number of times of validation printing (0 9)
F: Feed lines after printing of a difference subtoal (0 9 lines)
2615
.≈
009910
;
PrintKey operation
Example
2615
.
;
*ABCDEF
To program zero
Procedure
2615
PGM 2
Note
2617
.≈
30
;
PrintKey operation
Example
2617
.
;
To disable the alarm function
Time
1 to 255 seconds
Procedure
2617
PGM 2