Sharp ER-A420 Instruction Manual Page 167

  • Download
  • Add to my manuals
  • Print
  • Page
    / 171
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 166
165
The malfunctions shown in the left-hand column below, labelled “Fault,” do not necessarily indicate functional
faults of the machine. It is therefore advisable to refer to the “Checking” shown in the right-hand column before
calling for service.
Error message table
Fault Checking
The display won't be illuminated even when
the mode switch is turned to any other
position than “ ”.
• Is power supplied to the electrical outlet?
• Is the power cord plug out or loosely connected to the
electrical outlet?
(1)
The display is illuminated, but the whole machine
refuses registrations.
• Is a cashier code assigned to the register?
• Is a clerk code assigned to the register?
• Is the mode switch set properly at the “REG” position?
(2)
No receipt is issued. • Is the receipt paper roll properly installed?
• Is there a paper jam?
• Is the receipt function in the “OFF” status?
• Is the print head release lever at the printing position?
(3)
No journal paper is taken up. • Is the take-up spool installed on the bearing properly?
• Is there a paper jam?
(4)
Printing is unusual. • Is the print head release lever at the printing position?
• Is the paper roll properly installed?
(5)
Before calling for service
9
Text
Description
In default of
no. programming
1 Registration error ENTRY ERROR
2 Misoperation error MISOPERATION
3
Desired code is not
NO RECORD
programmed yet.
4 (Reserved)
5 Secret code error SECRET CODE
6 (Reserved)
7 Memory is full. MEMORY FULL
8 Insert slip paper. INSERT SLIP
9
The entered cashier code
NO AUTHORITY
is not authorized.
10 Stock is empty. OUT OF STOCK
11
Compulsory pushing
SBTL COMPUL.
the subtotal key
12 Compulsory tendering TEND COMPUL.
13 Compulsory PBAL PB COMPUL.
14-21 (Reserved)
22 Overlapped cashier error CASHIER ERR.
23 Cashier resetting over error ENTRY ERR CA
24-26 (Reserved)
27 Power off POWER OFF
28-30 (Reserved)
31 Compulsory non-add code # COMPULSORY
32
The cashier/clerk is not
NOT ASSIGNED
assigned.
33 (Reserved)
34 Overflow limitation OVER LIMIT.
Text
Description
In default of
no. programming
35
The open price entry is
INH. OPEN PR
inhibited.
36
The unit price entry is
INH. UNIT PR
inhibited.
The direct non-tendering
37 finalization after previous NOT NON-TEND
tender entry is inhibited.
38-66 (Reserved)
67 REG buffer is full. BUFFER FULL
68-71 (Reserved)
72 EFT error EFT ERROR
73 EFT connection is broken. EFT BREAK
74-75 (Reserved)
76
Closing the drawer is
CLOSE DRAWER
compulsory.
77-80 (Reserved)
81 Entry of secret code is needed. ENTR SECRET#
82-83 (Reserved)
84 Data backup send success SEND OK
85 Data backup receive success RECEIVE OK
86
Data backup communication
COM. ERROR
error
87 Backup data format error DATA ERROR
88 Data backup time out error TIME OUT
89-94 (Reserved)
95 EURO change compulsory EURO CHANGE
MAINTENANCE-A410/A420 02.4.20 6:51 PM Page 165
Page view 166
1 2 ... 162 163 164 165 166 167 168 169 170 171

Comments to this Manuals

No comments