LSM Operator Panel
2-6 Tenth Edition 9871
Table 2-2. LSM Operator Panel Status Screen
Item
1
Category Description
1 Status FUNC : INIT
Indicates that the LSM is performing initialization routines.
These routines are performed when the LSM has been
powered-on, when the access door has been closed, or when
the
IPL or the RESET switch has been pressed.
When the panel shows FUNC : INIT, the display area shows
diagnostic messages generated during initialization.
FUNC : OFFL
Indicates that the LSM is offline.
When the panel shows FUNC : OFFL, the display area shows
OFFLINE.
FUNC : ONLN
Indicates that the LSM is functioning and online.
When the panel shows FUNC : ONLN, the display area shows
status information about the CAPs and PCAP. Requests for you
to perform an action are also shown here.
2 Indicator Identifies the LSM number in the ACS.
3 Indicator Identifies the active LAN.
4 Indicator Blinking heart indicates processor is active.