The ZM-62E can connected with a general purpose computer using the user program (exclusive command
use). Refer to ZM (general purpose serial) users manual in detail.
When a computer and ZM-62E are 1 : 1
RS-232C can use it by less than 15m, and RS-422 (485) can use transmision distance by less than 500m.
Interruption processing can be used. (Switch ON/OFF, the write-in key of a ten-key, screen change)
General Purpose Serial
Communication
1 General Purpose Serial Communication
General purpose computer
RS-232C
RS-422
1: 1 connection
ZM-62E
POWER
RUN
ZM-62E ZM-62E
POWER
RUN
ZM-62E
POWER
RUN
POWER
RUN
General purpose computer
RS-422
1 : 1 connection
When a computer and ZM-
**
are 1 : n (Up to ZM-
**
32 sets are connectable.)
The command point needs to be station number specified.
Interruption processing cannot be used.(Switch ON/OFF, the write-in key of a ten-key, screen change)