E-37
Wired Remote Control Terminal Specifications
1. Specifications of wired remote control input
• 4.4ø minijack
• External: +5V (1A)
• Internal: GND
2. Function and transmission codes
VOLUME UP
VOLUME DOWN
POWER ON
POWER OFF
CURSOR UP
CURSOR DOWN
ADJUST UP
ADJUST DOWN
MUTE
MENU
E-ZOOM
VIDEO
RGB1
ENTER
LENS SELECT
CHANNEL CALL
RGB2
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C1
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C2
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C3
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C4
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C5
0
1
0
0
0
1
1
0
1
0
1
0
1
1
1
1
0
C6
0
0
1
1
0
0
1
0
1
0
1
1
0
1
1
1
1
C7
1
1
1
1
1
1
1
0
1
1
0
0
1
1
0
0
1
C8
0
0
0
0
1
1
1
0
0
0
0
0
0
0
1
1
0
C9
1
1
1
1
1
1
0
1
1
0
1
1
1
1
0
1
1
C10
0
0
0
0
0
0
0
0
0
0
1
1
1
0
0
0
1
C11
0
0
1
0
0
0
1
1
0
1
1
0
0
1
0
0
0
C12
0
0
0
1
1
1
0
0
0
1
1
0
0
0
1
0
0
C13
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
1
C14
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
0
C15
No. Control Item System Code Data Code External Code
(Function)
3. Sharp remote control signal format
1) Transmission format
a) 15-bit format
2) Wave form of output signal
Output using Pulse Position Modulation
“0”“1”“0”
D
“0”“0”“0”“1”
T
0
T
1
t
t = 264 µs
To = 1.05 ms
T1 = 2.10 ms
Pulse carrier frequency = 455/12 kHz
Duty ratio = 1:1
3) Transmission control code
a) 15 bit
Note:
To operate the MOUSE, L-CLICK and R-CLICK functions
through the wired remote control input, connect the cable from
the wired remote control (supplied) terminal on the projector to
the remote control. The codes for these functions are complex
and are, therefore, not listed here.
Wired remote control function code
10110********10
C1 System Code C5 C6 Data Code C13 C14 C15
LSB MSB
* System codes C1 to C5 are fixed at “10110”.
* Codes C14 and C15 are reverse confirmation bits, with
“10” indicating “Front” and “01” indicating “Rear”.
DDDDDD
DDDDDDD
67.5 ms 67.5 ms
b) Example of Reverse D to
D
C1 C2 C3 C4 C5 C6 C7 C8 C9 C10 C11 C12 C13 C14
System Address
D to D Common Data Bit Reverse in D
Function Key Data Bit
Data
Expansion
Data
Deter-
mination
Mask
C15
C1
1
DC2
0
C3
1
C4
1
C5
0
C6
1
C7
0
C8
0
C9
0
C10
0
C11
0
C12
0
C13
0
C14
1
C15
0
C1
1
DC2
0
C3
1
C4
1
C5
0
C6
0
C7
1
C8
1
C9
1
C10
1
C11
1
C12
1
C13
1
C14
0
C15
1
t
26.4 µs
Page view 36
1 2 ... 32 33 34 35 36 37 38 39

Comments to this Manuals