Sharp R-360ES Specifications Page 80

  • Download
  • Add to my manuals
  • Print
  • Page
    / 392
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 79
3A-10 P/N 13999-002 Info Manual
Section 3A Cirrus Design
Abnormal Procedures SR20
Communications Failure
Communications failure can occur for a variety of reasons. If, after
following the checklist procedure, communication is not restored,
proceed with FAR/AIM lost communications procedures.
• Note •
In the event of an audio panel power failure the audio panel
connects COM 1 to the pilot’s headset and speakers. Setting
the audio panel ‘Off’ will also connect COM 1 to the pilot’s
headsets and speakers.
1. Switches, Controls ............................................................. CHECK
2. Frequency ....................................................................... CHANGE
3. Circuit Breakers.................................................................. CHECK
4. Headset........................................................................... CHANGE
5. Hand Held Microphone ................................................. CONNECT
September 2011
Page view 79
1 2 ... 75 76 77 78 79 80 81 82 83 84 85 ... 391 392

Comments to this Manuals

No comments