Page view 29
18 Endcaps
MX1 Reference Guide E-EQ-MX1RG-D
Tools Required: #1 Phillips Screwdriver
1. ZIF Connector
2. Rubber O-Ring Gasket
3. O-Ring Gasket Slot
Figure 1-16 MX1 Endcap with O-Ring Gasket
1. ZIF Connector
2. ZIF Cable or Ribbon
Cable
3. Curved Edge
4. Middle Screw Set
Figure 1-17 Endcap and ZIF Ribbon Connector
Removal
1. Using a #1 Phillips screwdriver, remove the two screws securing the endcap. These screws
are located on the upper rear of the unit.
2. Loosen the two screws in the middle (number 4 on the figure titled “Endcap and ZIF Ribbon
Connector”. Do not remove middle screws.
3. When the top screws are removed detach the endcap and separate it from the MX1 unit no
more than the length of the ribbon connector still connecting the endcap to the unit.
4. Carefully lift up the lock mechanism on the ZIF connector.
Note: Use caution when performing this task since excessive pulling or twisting of the
connector may result in damage to either the unit, the endcap and/or the ribbon
connector.
5. Disconnect the ribbon cable from the ZIF connector in the endcap only.
6. If you anticipate keeping the endcap removed from the unit for a long period of time place the
endcap in an enclosed storage container. Store in an area that is protected from dirt, moisture,
and electrostatic contact.