AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 1
[9] TROUBLE CODE LIST
1. List
Trouble code
Trouble contents
Trouble
detection
Main
code
Sub
code
A0 01 Security incompatibility error
E1 00 IMC PWB communication trouble MCU
10 IMC PWB trouble
11 IMC PWB ASIC error
12 IMC PWB CODEC IC error
13 IMC PWB flash ROM error
14 IMC PWB expaned memory module
(DIMM) error
15 IMC PWB page memory error
/SRAM error
16 IMC PWB standard compression memory
error
17 IMC PWB smoothing IC error
80 IMC PWB communication trouble
(protocol)
81 IMC PWB communication trouble
(Parity)
82 IMC PWB communication trouble
(Overrun)
84 IMC PWB communication trouble
(Framing)
88 IMC PWB communication trouble
(Time-out)
E7 02 LSU trouble
10 CCD black level error
11 CCD white level error
12 Shading trouble
F1 00 Finisher communication trouble
(AR-FN5A)
FIN
01 Side guide plated home position error
(AR-FN5A)
03 Paddle motor trouble (AR-F14N)
06 Offset motor trouble (AR-FN5A)
Slide motor trouble (AR-F14N)
08 Staple motor error (AR-FN5A)
10 Staple motor trouble (AR-F14N)
11 Rear edge plate home position error
(AR-FN5A)
!"#$%&'&()*'+,*,-'*-,".%&'/0 123 4567
15 Finisher lift-up motor trouble
19 Alignment motor (F) trouble (AR-F14N)
20 Alignment motor (R) trouble (AR-F14N)
30 Finisher interface error (AR-F14N)
31 Fold sensor trouble (AR-F14N)
32 Punch unit communication trouble
(AR-F14N)
33 Punch side registration motor trouble
(AR-F14N)
34 Punch motor trouble (AR-F14N)
35 Punch side registration sensor trouble
(AR-F14N)
36 Punch registration sensor trouble
(AR-F14N)
37 Backup RAM trouble (AR-F14N)
38 Punch backup RAM trouble (AR-F14N)
39 Punch dust sensor trouble (AR-F14N)
40 Punch power trouble (AR-F14N)
50 Finisher incompatibility error
53 Interface transport unit connection trouble
(AR-F14N)
81 Transport motor trouble (AR-F14N)
F2 02 Toner supply failure
04 Identification error
Model error
Ty pe er ro r
Destination error
Data abnormality
Misc error
58 Temperature humidity sensor abnormality
F5 02 Copy lamp (xenon lamp) error
F6 00 FAX control PWB communication trouble MCU
10 FAX control PWB trouble
80 FAX control PWB communication trouble
(Protocol)
81 FAX control PWB communication trouble
(Parity)
82 FAX control PWB communication trouble
(Overrun)
84 FAX control PWB communication trouble
(Framing)
88 FAX control PWB communication trouble
(Time-out)
95 Incompatibility error of AR-F14N and FAX
control PWB
99 FAX control PWB destination error
F9 00 Printer PWB communication trouble MCU
10 Printer PWB trouble
80 Printer PWB communication trouble
(Protocol)
81 Printer PWB communication trouble
(Parity)
82 Printer PWB communication trouble
(Overrun)
84 Printer PWB communication trouble
(Framing)
88 Printer PWB communication trouble
(Time-out)
95 Incompatibility error of AR-F14N and PCL/
GDI PWB
96 PCL PWB incompatibility error
99 Printer PWB language error
H2 00 Main heater lamp thermistor open hard
detection
01 Sub heater lamp thermistor open hard
detection
H3 00 Main heater lamp abnormally high
temperature hard detection trouble
01 Sub heater lamp abnormally high
temperature hard detection trouble
10 Main heater lamp abnormally high
temperature soft detection trouble
11 Sub heater lamp abnormally high
temperature soft detection trouble
H4 00 Main heater lamp abnormally low
temperature detection
01 Sub heater lamp abnormally low
temperature detection
20 Main heater lamp abnormally low
temperature detection
21 Sub heater lamp abnormally low
temperature detection
H5 01 10 times of continuous detection of the
lower paper exit sensor (POD1) lead edge
jam or the upper paper exit sensor
(POD2) lead edge jam or the duplex
sensor (PPD2) rear edge jam
L1 00 Scanner feed trouble
L3 00 Scanner return trouble
Trouble code
Trouble contents
Trouble
detection
Main
code
Sub
code
SHARP TROUBLE & ERROR CODES
AR-M256, AR-M257, AR-M258, AR-M316, AR-M317, AR-M318
Page view 0
1 2 3 4 5 6 ... 11 12

Summary of Contents

Page 1 - [9] TROUBLE CODE LIST

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 1[9] TROUBLE CODE LIST1. ListTrouble codeTrouble contentsTrouble detectionMain codeS

Page 2

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 10H4 21 Content Sub heater lamp abnormally low temperature detectionDetails The setu

Page 3

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 11L4 11 Content Shifter motor troubleDetails The shifter home position detection sig

Page 4

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 12U9 81 Content Operation control PWB communication trouble (Parity)Details Communic

Page 5

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 2!" #$%&'()*+,-./)0.L4 01 Main motor trouble11 Shifter motor troubleL6

Page 6

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 3E1 80 Content IMC PWB communication trouble (protocol)Details Communication trouble

Page 7

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 4F1 00 Content Finisher communication troubleDetails Communication line test error o

Page 8

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 5F1 20 Content Alignment motor (R) trouble (AR-F14N)Details Alignment motor operatio

Page 9

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 6F1 81 Content Transport motor trouble (AR-F14N)Details M-9#F@,-*'+,*,-'*-

Page 10

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 7F6 82 Content FAX control PWB communication trouble (Overrun)Details Communication

Page 11

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 8F9 84 Content Printer PWB communication trouble (Framing)Details Communication trou

Page 12

AR-M256/M257/M258/M316/M317/M318/5625/5631 TROUBLE CODE LIST 9 - 9H3 11 Content Sub heater lamp abnormally high temperature soft detection troubleDet

Comments to this Manuals

No comments