Page view 251
250
E-pay device PIN pad (9 SYSTEM
3 EPAY DEVICE PRESET
2 PIN PAD .......... PGM2)
(1) Select the PGM2 mode and touch the [2 POS SETTING] to perform the programming.
(2) Touch the [9 SYSTEM] button to display the menu, and touch the [3 EPAY DEVICE PRESET] button to
display the detail menu. Then touch the [2 PIN PAD] button to program.
(3) Touch the required program item, and enter each parameter and touch the [ENTER] key.
Repeat this step (3) satisfactorily.
(4) To terminate the programming, touch the [EXIT] key.
Text Parameter
CHANNEL# 0 5: 0 means no RS-232 channel is assigned.
TIME OUT1 Time out timer for ACK/NAK: 3 digits (1 to 255 (sec): 10)
TIME OUT2 Time out timer for response of PIN data: 3 digits (1 to 255 (sec): 99)
Transmission data rate (baud rate)
19200 bps:
9600 bps:
BAUD RATE 4800 bps:
2400 bps:
1200 bps:
300 bps:
E-pay device IC card (9 SYSTEM
3 EPAY DEVICE PRESET
3 IC CARD .......... PGM2)
(1) Select the PGM2 mode and touch the [2 POS SETTING] to perform the programming.
(2) Touch the [9 SYSTEM] button to display the menu, and touch the [3 EPAY DEVICE PRESET] button to
display the detail menu. Then touch the [3 IC CARD] button to program.
(3) Touch the required program item, and enter each parameter and touch the [ENTER] key.
Repeat this step (3) satisfactorily.
(4) To terminate the programming, touch the [EXIT] key.
Text Parameter
CHANNEL# 0 5 0 means no RS-232 channel is assigned.
TIME OUT1 Time out timer: 3 digits (1 to 255 (sec): 60)