ENGLISH
FEATURES
Plasmacluster Ion Control
The unit controls the ratio of negative ions
and positive ions depending on the con-
dition of the room.
• Clean Mode
Approximately the same numbers of posi-
tive and negative ions are discharged.
• Ion Control Mode
Plenty of negative ions exist in natural
surroundings such as waterfalls or forests.
In this mode, negative ions will be re-
leased in an increased rate, in order to
bring the room air close to this natural
environment.
• AUTO Plasmacluster Ion Mode
The unit will switch between Clean Mode
and Ion Control Mode automatically de-
pending on the amount of impurities in the
air detected by the dust and odor sensor.
• Filters
1) Pre-Filter
It collects large particles.
2) Washable Active Carbon Filter
Its deodorizing performance can be
maintained by washing.
3) True HEPA (High Efficiency
Particulate Air) Filter with anti-
bacterial Apatite Filter
High-efficiency particle collection in-
cluding pollen and dust.
CONTENTS
• FOR YOUR PROTECTION (U.S.) ...............E-2
• CONSUMER LIMITED WARRANTY (U.S.) .E-3
• FOR YOUR PROTECTION (CANADA) .......E-4
• LIMITED WARRANTY (CANADA) ...............E-5
SAFETY PRECAUTIONS........................ E-6
• RISK OF ELECTRIC SHOCK ......................E-6
• CAUTIONS CONCERNING THE
OPERATION OF THIS PRODUCT ..............E-7
• REMOTE CONTROL LIMITATIONS ............E-7
• INSTALLATION GUIDELINE........................E-7
• FILTER GUIDELINES ..................................E-7
PART NAMES.......................................... E-8
• MAIN UNIT DISPLAY...................................E-8
• BACK ...........................................................E-9
• ACCESSORIES ...........................................E-9
• MOUNTING THE STAND ............................E-9
PREPARATION...................................... E-10
• FILTER INSTALLATION ............................ E-10
• INSERTING BATTERIES
IN THE REMOTE CONTROL ................... E-10
• REMOTE CONTROL USE.........................E-11
OPERATION ..........................................E-12
• MAIN UNIT OPERATION.......................... E-12
• REMOTE CONTROL OPERATION .......... E-13
CARE AND MAINTENANCE................. E-14
•WASHABLE ACTIVE CARBON
FILTER CARE ........................................... E-14
• FILTER CLEANING................................... E-15
• MAIN UNIT................................................ E-16
• ODOR SENSOR ....................................... E-16
• FILTER REPLACEMENT
GUIDELINES ............................................ E-17
OPERATION GUIDE.............................. E-18
TROUBLE SHOOTING.......................... E-19
SPECIFICATIONS ................................. E-20
Thank you for purchasing the SHARP FP-N40CX.
Please read this manual carefully for the correct
usage information. Before using this product, be
sure to read the section: “Safety Precautions.”
After reading this manual, retain it in a conven-
ient location for future reference.
This product is for household use only.
E-1
FILTER MAINTENANCE
Some odor ingredients absorbed by
the filters may become separated and
may be discharged through the air
outlet and result in additional odor.
Depending on the usage environ-
ment, the air outlet odor may become
strong after several months.
In this case, clean the Washable Ac-
tive Carbon Filter. (Refer to E-14)
If this odor persists, this is because
the odor components absorbed by the
HEPA Filter have come off the filter.
Purchase the optional filter FZ-
N40HFU and replace the original fil-
ters.
ENGLISH