22
XV-DW100U
Replacing the LCDs
With the top cabinet removed
(1) Disconnect the LCD flat cable from the output PWB connector.
(2) Remove the lock screws "b" and "c". Detach the R/B adjusting plate or the G adjusting plate together with the LCD
panel.
(3) Separate the LCD panel from the adjusting plate.
(4) Mount a new LCD panel in the reverse order of the above steps (1), (2) and (3).
~ Readjust the convergence and focus. Note that the G-LCD panel needs no convergence adjustment and has
a small adjustment range in the Z direction.
G-LCD panel
mounting screws
Lock
screws "c"
Lock screws "c"
Lock
screws "b"
FRONT
SIDE VIEW
TOP VIEW
SIDE VIEW
RB-LCD panel
mounting screws
Lock screws "c"
X
Z
θY
X
Y
θZ
RB adjusting plate
RB-LCD
G-LCD
~
R-LCD
B-LCD
X
Z
θY
G-LCD
G adjusting plate
2
2
2
2
3
3
Page view 21