REMOVING OF MAJOR PARTS
1. Removing the Intake cover, lamp unit and lens cover.
1-1. Detach the Intake cover.
1-2. Remove the four lock screws off the inner filter frame. Detach the frame.
1-3. Remove the lock screw off the lamp cover. Slide and detach the lamp cover.
1-4. Remove the three lock screws off the lamp unit and detach the lamp unit.
1-5. Remove the lens cover lock screw, and turn and detach the lens cover.
2. Removing the rear cabinet.
2-1. Remove the four lock screws off the terminal board.
2-2. Remove the six lock screws off the rear cabinet. Detach the rear cabinet.
1-4
1-1
1-2
1-3
1-5
2-1
2-2
Intake Cover
Inner Filter Frame
Lens Cover
Lamp Cover
Rear Cabinet
Lamp Unit