10 LokSoundXL User Manual V2.1 05/2002
precise.) They are easy to install. A commonly used
module is the Siemens / Infineon TLE4905 available at
electronic stores.
Connect terminal Vs of TLE4905 to terminals 1-4,
GMD to terminal 1-4 and Pin Output to terminal 1-7.
Before you can use the wheel sensor certain CVs
have to be set. See chapter 5.2.4
3.7.4 Connecting auxiliary reed switches
As from version 2.0 the LokSoundXL decoder has
two additional inputs. You can use them to release
sound effects with the help of trackside magnets.
Just connect a reed sensor to the inputs and place a
magnet at the appropriate location on the layout.
The required sound effect will be activated every time
the locomotive passes the magnet.
With the aid if these inputs users of LGB MZS with
Lokmaus may activate the multitude of sound effects
generated by LokSoundXL decoders.
Both inputs REED-IN1 and REED-IN2 share
terminal 2-7 as well as 2-8 with function outputs
AUX5 and AUX6. If you want to use the REED-
IN functions then AUX5 and 6 are not available.
Before you can use reed sensors certain CVs
have to be set. See chapter 5.2.7
4. Set Up and installation of the decoder
After successful installation you may operate the
decoder.
But first you will find out how to check your
installation. In chapter 4.1 you will find instruction of
how to operate the decoder in analogue mode. In
chapter 4.2 you learn how to operate it with various
digital systems.
Before changing any decoder settings (e.g. locomotive
address, sound volume) we recommend to read
chapter 5 . There you find out which parameters are
available and how they may be altered with the
commonly available DCC command centers.
After installation you may test the LokSoundXL
decoder as follows.
Please inspect all connections carefully using an
ohmmeter: are there any short circuits between
the motor terminals and the wheel pick-ups?
Have all connections between motor terminals
and the chassis been isolated? Are bulbs
connected properly and isolated from the
chassis? Is the decoder installed safely to avoid
contact with the chassis? Is there sufficient space
around the LokSoundXL decoder to allow for
cooling? Could the LokSound 2 decoder or any
of the wires be squeezed when refitting the
housing? May sound emit from the locomotive
without obstruction?
Connecting auxiliary reed switches
figure 8figure 8
figure 8figure 8
figure 8: connecting a Hall sensor
1-1
1-2
1-3
1-4
1-5
1-6
1-7
1-8
1-9
GND
Output
Vs
TLE4905
driving axle
Miniature magnet
resistor 10k 0,25W
Reed switches
REED-IN1
REED-IN2
figure 9figure 9
figure 9figure 9
figure 9: connecting auxiliary reed switches
1-1
1-2
1-3
1-4
1-5
1-6
1-7
1-8
1-9