[10] SERVICING AT MEMORY
TROUBLE AND MAIN
CONTROL PWB REPLACEMENT
1. General
The control PWB stores various set values, adjustment values, and
counter values.
These data are very important and used for operating the machine
properly and for service control.
In the following cases, therefore, various set values, adjustment
values and counter values must be set again.
@
When a memory trouble (U2) occurs.
@
When the EEPROM in the main control PWB is replaced.
@
When the main control PWB is replaced.
When "U2" trouble occurs, the data cannot be relied upon, and they
must be set properly.
2. Purpose
The purpose is to reset the memory data to operate the machine
properly.
Use the attached service memory data recording sheet to memorize
the newest data when servicing in order to cope with the above
situations. This improves efficiency in servicing and realizes quick
recovery.
3. Remedies
Perform the procedures according to the following flowcharts.
"Sim" in the flowchart means "Simulation."
Memory trouble
Procedures for memory trouble, main control PWB replacement,
and main control PWB EEPROM replacement
NO
YES
"U2" trouble
occurs
Do you replace
the main control
PWB?
Replace the main
control PWB
Cancel "U2" trouble
with simulation 16
1
Repair the
defective section
NO
YES
Is the
EEPROM in
the main control
PWB defective?
Replace the main
control PWB
Mount the EEPROM of
the old main control to
the new main control
Replace the main
control PWB
End
Replace the
EEPROM in the
main control PWB
1
Replace the EEPROM
Clear the drum counter
with Sim 24-7.
Reset the maintenance
counter with Sim 20-1.
10 – 1