Sharp SF-1014 Service Manual Page 44

  • Download
  • Add to my manuals
  • Print
  • Page
    / 153
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 43
4. Optical system
4-1. Copy lamp replacement
1 Open the body up. Release the lock lever of the manual paper
feed unit and remove the manual paper feed unit.
2 Remove the fixing screws (2 pcs.) in the right upper cabinet, and
remove the right upper cabinet.
3 Remove the fixing screws (4 pcs.) of the glass holder, and remove
the glass holder.
4 Remove the table glass.
5 While pushing the copy lamp electrode in the rear frame, remove
the copy lamp.
For assembly, reverse the disassembly procedure.
Note: Be careful to the direction of the copy lamp installation.
4-2. Copy lamp unit replacement
1 Remove the manual paper feed unit, the right upper cabinet, the
glass holder, the table glass, and the operation panel.
2 Move the copy lamp unit to the frame notch (refer to the figure).
3 Remove the terminal section of the copy lamp lead wire. (One
screw and insertion terminal)
4 Loosen the fixing screw of the front and the rear frame wire, fixing
plate and remove the wire from the copy lamp unit.
5 Slide the whole unit forward, and remove the rear frame side
upwards.
For assembly, reverse the disassembly procedures.
Note: When the copy lamp unit is removed, the position adjustment
must be required when attaching again. Refer to the adjust-
ment item for the work.
4-3. Mirror base drive wire replacement
<Removal>
1 Remove the manual paper feed unit, the right upper cabinet, the
glass holder, the table glass and the operation panel.
2 Remove the fixing screws (2 pcs.) of the left upper cabinet, and
slide to the rear frame side to remove the cabinet.
3 Loosen the fixing screw of the copy lamp unit wire fixing plate, and
remove the wire from the unit.
4 Remove the tension spring (7 in the figure) of the mirror base
drive wire in the paper exit side from the hook section.
5 Slightly shift the mirror base to the paper feed side, and remove
the terminal 1 of the mirror base drive wire.
6 Remove the wire fixing screw of the drive pulley.
<Installation>
1 Set the mirror base to the positioning plate position.
2 Set the terminal side of the mirror base drive wire on the hook
section 1, turn the mirror base pulley 2 outside to wind the wire
around the drive pulley from the above.
3 Wind the wire 8 turns from the outside to the inside of the drive
pulley, and put the 7th turn into the groove, and fix it with a screw
temporarily.
4 Pass the wire under the mirror base and wind around the paper
exit pulley (the larger one).
5 Pass the wire to the inside of the mirror base pulley, and pass
through the paper exit pulley (the smaller one), then fix the tension
spring to the hook section 7.
6 Check that the mirror base is in contact with the positioning plate,
and tighten the wire fixing screw of the drive pulley.
Wire fixing screw
Wire fixing screw
6 – 9
Page view 43
1 2 ... 39 40 41 42 43 44 45 46 47 48 49 ... 152 153

Comments to this Manuals

No comments