Page view 101
5. Memory simulation list
Purpose/kind Section
Contents
Ref. page
Main
code
Sub
code
Default
value
Description
Adjustment Paper feed
section
51 2 50 Adjustment value of contact pressure of the paper on the main
body resist roller
8-3
Optical unit 26 8 11 Adjustment value (lens shift amount adjustment value) of copy
magnification ratio in zoom copying
7-16
45 1 50 Adjustment value of copy paper lead edge void amount 7-20
46 1 Adjustment value of copy density (exposure level) in each copy
mode and of copy density gradient (exposure gradient)
7-26
Manual copy mode density level 1 (Not toner save mode)
Manual copy mode density level 5 (Not toner save mode)
Manual copy mode density level 1 (Toner save mode)
Manual copy mode density level 5 (Toner save mode)
Auto copy mode density level 1 (Not toner save mode)
Auto copy mode density level 5 (Not toner save mode)
Auto copy mode density level 1 (Toner save mode)
Auto copy mode density level 5 (Toner save mode)
Photo copy mode density level 1 (Not toner save mode)
Photo copy mode density level 5 (Not toner save mode)
47 The AE sensor and the optical section characteristics memory data
for the change in the copy lamp application voltage
7-26
48 1 50 The vertical copy magnification ratio adjustment value 7-15
2 50 The horizontal copy magnification ratio adjustment value (when the
document table is used)
7-16
50 1 The adjustment value of copy image position on the copy paper 7-19
50 Set value A
50 Set value B
50 Set value C
Process 44 1 Process correction mode setting
Developer unit 25 2 Toner density initial set value 4-5
SPF unit 48 3 50 The horizontal copy magnification ratio adjustment value (when the
document table is used)
7-18
51 2 50 The adjustment value of contact pressure between the SPF resist
roller and the document
8-3
6 Adjusting value of copy density in the SPF mode 7-28
Setting Specifications 26 6 Specifications setting by destination 8-8
Setting Fuser unit 26 13 0 Setting of the main motor operation mode in warming up. 8-8
43 1 185°C Fusing temperature set value 8-8
2 0 Fusing temperature setting value in the power save mode 8-8
Process 44 1 16 Picture correction mode function setting
Data
JAPAN 00
SEC 01
SECL 02
SEEG 03
SUK 04
SCA 05
Inch series 06
AB series 07
LAG Inch series 08
LAG AB series 11
Code
No.
Operation
mode
Operation
0
Normal
mode
When the fusing temperature reaches
the specified level, the main motor stops.
1
Long
mode
The main motor keeps rotating until the
completion of the warming up.
10 – 5