Page view 35
35
7. Downloading the contents of the IRC programming to
satellites master
When you have completed or changed the IRC programming, distribute the IRC preset data
from the master to all satellites in the IRC system.
(1) Initial downloading
For initial setup of the IRC system, use this downloading method. The preset data in the
master is downloaded to each satellite, when the existing preset data in the satellite is
cleared.
1.
Enter the PGM2 mode.
2.
Select “INITIAL D/L” and press the [ENTER] key.
The INITIAL D/L menu will open.
3.
In order to distribute all preset data files in the master
to satellites, select “ALL PGM” and press the [ENTER]
key.
In order to distribute an individual preset data file,
select the corresponding item and press the [ENTER]
key.
For initial downloading of PLU preset data, it is
necessary to enter the code range and machine
numbers to receive the data.
NOTE: 25 ALL PGM will clear the satellites
totalizers.
4.
If you wish to download the IRC programming data to
all satellites, select “ALL” and press the [ENTER] key.
If you wish to download the data to certain satellite(s),
select “MACHINE SELECT” and press the [ENTER]
key. In this case, the “MACHINE SELECT” menu will
open. Move the cursor to the machine numbers and
select “YES.”
NOTE
Check the contents of the programming of all the satellites in the IRC system that have received
the preset data.