Sharp ER-A770 Instruction Manual Page 15

  • Download
  • Add to my manuals
  • Print
  • Page
    / 71
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 14
14
9. T-LOG polling
All REG-mode transaction data in each satellite is saved in its T-LOG buffer. T-LOG polling is a
data collecting system in which the master collects data from the T-LOG buffers in satellites.
T-LOG polling becomes available upon open-store operation and becomes unavailable upon
close store operation.
A request for T-LOG polling is issued from the satellite to the master when the number of data
records in its T-LOG buffer exceeds a predetermined number in the open store state.
As the master detects such a request, it starts collecting the T-LOG buffer data. After collection
of the data from one satellite, the master waits for a preset time and starts collecting data from
another satellite. In T-LOG polling, the data transmitted to the master is stored in the
corresponding file.
The data flow in T-LOG polling is shown below.
Polling sequence (see the figure above)
(1) Satellite A makes a request for polling.
(2) The master detects the request and starts collecting T-LOG data from satellite A.
(3) The T-LOG data is sent to the master.
(4) After receiving T-LOG data from satellite A, the master waits for a preset time.
(5) The master detects a request from another satellite (B, C or D) and starts polling for it.
If its T-LOG buffer becomes full, registration will be disallowed at a satellite when it has been
programmed for “LOCK UP,” and allowed when it has been programmed for “CONTINUE.” For
how to specify whether the registration is disabled or enabled when the T-LOG buffer becomes
full, please refer to the ER-A770 instruction manual.
Master
Satellite A Satellite B Satellite C Satellite D
(4)
(1)
(2)
(3) (5)
Page view 14