Sharp MD X5 Service Manual Page 71

  • Download
  • Add to my manuals
  • Print
  • Page
    / 104
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 70
– 71 –
MD-X5H/CP-X5H
• Check the tracking system.
Data cannot be read.
Check the waveform of IC1 pin 7 (TE).
The waveform shown in Figure 71 appears.
The discless state appears soon.
Yes
Check the periphery from the IC1 pin 8
to pin 15, from IC5 to CNP2.
The tracking servo does not
operate.
Check the VCO-PLL system.
No
Yes
Playback is enabled in the TEST mode.
Yes
Normal jump is
impeded, and top
of music number is
not found.
Although IL is
possible, playback is
impossible.
Yes
Yes
Check the periphery
of IC1 pin 14.
Figure 71
3
4
5ms
1.00 V
IC1 7 TE
5 ms
5.0 V
IC1 54 DRF
• Check the spindle system
Yes
Yes
Playback operation is done without disc.
The turntable rotates insignificantly.
The turntable does not rotate or rotates with high speed.
The spindle driver is normal.
No
Check the periphery from IC1 pin 23 to pin 27, pin 39, pin 40, IC2
pin 12, pin 13, from IC5 to CNP3.
No
Page view 70