Sharp MD X5 Service Manual Page 17

  • Download
  • Add to my manuals
  • Print
  • Page
    / 104
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 16
– 17 –
MD-X5H/CP-X5H
No
ASPM, summary operation
Hold down the ASPM button for 3 more second.
“ASPM” blinks in the display.
Preset CH memory full over?
No operate. After displayed “0 MEMORY END”.
Return to previous station.
SD (TUNE) DET out OK?
If count 1st OK?
If count 2nd OK?
RDS signal or not? PI—identify
Comparing PI cord same or not?
between current receiving PI and
before PI which is already memorized
by ASPM on this time.
Comparing freg. same or not?
between current receiving frequency
and (already) previously memorized
frequency.
Memorized to the lowest
vacant preset channel.
Preset CH memory become full over?
Begin to ASPM SCAN from the next
CH-SPAN again.
Repeat and continue with same format
ASPM operation untill 108 MHz.
After reached 108 MHz, displayed the
TTL quantity of memorized stations.
And return to the previous receiving
freq. automatically.
Displayed the TTL quantity of memo-
rized stations by ASPM operation on
this time. And return to the previous
receiving freq. automatically.
Ye s
No
Ye s
Ye s
Ye s
Ye s
No
No
No
No
No
No
Effect
Pass
No effect
Pass
No effect
Pass
No effect
Pass
No effect
Ye s
No
Ye s
Compare the field strength of current
receiving signal. Is receiving signal
stronger than signal which has same PI
cord and is already memorized to
preset memory ahead of this receiving
time?
Ye s
No effect
No
No effect
Comparing freg. same or not?
Between current receiving frequency
and (already) previously memorized
frequency.
Ye s
Memorized to the lowest
vacant preset channel.
Ye s
No effect
Begin to scan start 87.50 108.00 MHz
Page view 16
1 2 ... 12 13 14 15 16 17 18 19 20 21 22 ... 103 104

Comments to this Manuals