Criteria
Supporting Features Remarks and explanations
(f) When products deliver voice output in a public
area, incremental volume control shall be provided
with output amplification up to a level of at least 65
dB. Where the ambient noise level of the
environment is above 45 dB, a volume gain of at
least 20 dB above the ambient level shall be user
selectable. A function shall be provided to
automatically reset the volume to the default level
after every use.
Not Applicable There is no voice output in a public area.
(g) Color coding shall not be used as the only means
of conveying information, indicating an action,
prompting a response, or distinguishing a visual
element.
Not Applicable
There is no color touch panel.
(h) When a product permits a user to adjust color
and contrast settings, a range of color selections
capable of producing a variety of contrast levels shall
be provided.
Not Applicable There is no color display.
(i) Products shall be designed to avoid causing the
screen to flicker with a frequency greater than 2 Hz
and lower than 55 Hz.
Supports Applicable
(j) (1) Products which are freestanding, non-portable,
and intended to be used in one location and which
have operable controls shall comply with the
following: The position of any operable control shall
be determined with respect to a vertical plane, which
is 48 inches in length, centered on the operable
control, and at the maximum protrusion of the
product within the 48 inch length on products which
are freestanding, non-portable, and intended to be
used in one location and which have operable
controls.
Supports Applicable
(j)(2) Products which are freestanding, non-portable,
and intended to be used in one location and which
have operable controls shall comply with the
following: Where any operable control is 10 inches or
less behind the reference plane, the height shall be
54 inches maximum and 15 inches minimum above
the floor.
Supports
Applicable
Operable control is 6 inches behind the reference plane.
The height is 45 inches above the floor.
Platen cover also meets with requirement in (j)-2
because it can be stopped at any position.
(j)(3) Products which are freestanding, non-portable,
and intended to be used in one location and which
have operable controls shall comply with the
following: Where any operable control is more than
10 inches and not more than 24 inches behind the
reference plane, the height shall be 46 inches
maximum and 15 inches minimum above the floor.
(j)(4) Products which are freestanding, non-portable,
and intended to be used in one location and which
have operable controls shall comply with the
following: Operable controls shall not be more than
24 inches behind the reference plane.
Return to the top of the page.