INVERTER
FR-A800
INSTALLATION GUIDELINE
FR-A820-00046(0.4K) to 04750(90K)
FR-A840-00023(0.4K) to 06830(280K)
FR-A842-07700(315K) to 12120(500K)
FR-A846-00023(0.4K) to 00470(18.5K)
CONTENTS
PDF file · ·
Summary of Contents
INVERTER FR-A800 INSTALLATION GUIDELINE FR-A820-00046(0.4K) to 04750(90K) FR-A840-00023(0.4K) to 06830(280K) FR-A842-07700(315K) to 12120(500K)…
Print Date Art. no. Revision 11/2013 pdp 274662-A First edition 04/2014 akl 274662-B Addition: Changes: FR-A840-03250(110K) to 06830(280K) Parameter…
Electric Shock Prevention Fire Prevention This section is specifically about safety matters Do not attempt to install, operate, maintain or inspect…
Injury Prevention Additional Instructions Also note the following points to prevent an accidental failure, injury, electric shock, etc. Transportation…
Operation Emergency stop Maintenance, inspection and parts replacement When you have chosen the retry function, stay away from the equipment as it…
Disposing of the inverter For IP55 compatible models: Waterproof and dustproof performances Treat as industrial waste. General instructions Many of…
1 INSTALLATION AND INSTRUCTIONS *1 Specification differs by the type as follows *2 Standard models and separated converter types only. Type Monitor…
INSTALLATION AND INSTRUCTIONS 1.2 Installation of the inverter 1.3 Environment Before installation, check that the environment meets following…
2 OUTLINE DRAWING (Unit: mm) Inverter Type W W1 H H1 D C 200V class FR-A820-00046(0.4K) 110 95 260 245 110 6 FR-A820-00077(0.75K) 125…
OUTLINE DRAWING For dimensions of the converter unit (FR-CC2) refer to the FR-CC2 Instruction Manual. (Unit: mm) Inverter Type W W1 H H1 D C 400V…
1 Terminal connection diagrams 3.1.1 FR-A820/A840 FM type For footnotes *1 to *12 refer to next page. 3 3 35 13 MCCB R/L1 S/L2 T/L3 R1/L11…
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher, or if using a motor with a capacity of 75 kW or higher, always connect a DC…
CA type For footnotes *1 to *10 refer to next page. 3 3 35 13 MCCB R/L1 S/L2 T/L3 R1/L11 S1/L21 PC 10E(+10V) 10(+5V) 2 2 3 1 1 4 F/C (CA) C1 B1…
For the FR-A820-03800(75K) or higher and FR-A840-02160(75K) or higher, or if using a motor with a capacity of 75 kW or higher, always connect a DC…
1.2 FR-A842 FM type For footnotes *1 to *11 refer to next page. Note The FR-A842 models must be operated with a converter unit (FR-CC2), which has to…
The terminals R1/L11 and S1/L21 are connected to the terminals P/+ and N/– with a jumper respectively. When using separate power supply for the…
CA type For footnotes *1 to *9 refer to next page. Note The FR-A842 models must be operated with a converter unit (FR-CC2), which has to be operated…
The terminals R1/L11 and S1/L21 are connected to the terminals P/+ and N/– with a jumper respectively. When using separate power supply for the…
1.3 FR-A846 FM type For footnotes *1 to *8 refer to next page. R/L1 S/L2 T/L3 PC 10E(+10V) 10(+5V) 2 2 3 1 1 4 F/C (FM) SD C1 B1 A1 U V W P1 +- (-)…
No input voltage is allowed for these terminals.The function of these terminals can be changed with the input terminal assignment (Pr. 178 to Pr.…
CA type For footnotes *1 to *6 refer to next page. F/C (CA) R/L1 S/L2 T/L3 PC 10E(+10V) 10(+5V) 2 2 3 1 1 4 C1 B1 A1 U V W P1 (-) (+) AM 5 C2 B2 A2 M…
No input voltage is allowed for these terminals.The function of these terminals can be changed with the input terminal assignment (Pr. 178 to Pr.…
2 Main circuit terminal 3.2.1 Terminal layout and wiring For footnotes *1 to *3 refer to next page. FR-A820-00046(0.4K), 00077(0.75K)…
The following diagram shows the positions of R1/L11, S1/L21, and the charge lamp. *2 The terminals P3 and PR of the FR-A820-01540(30K) are not…
3 Wiring fundamentals 3.3.1 Cable size Select the recommended cable size to ensure that a voltage drop will be 2% max. If the wiring distance is long…
400V class, FR-A840/A846 (when input power supply is 440V based on the rated current for 150% overload for 1 minute) For footnotes *1 to *4 refer to…
For the FR-A840-01800(55K) or lower and the FR-A846 (IP55 compatible) models, the recommended cable size is that of the HIV cable (600V class 2…
3.2 Total wiring length With general-purpose motor Connect one or more general-purpose motors within the total wiring length shown in the following…
4 Control circuit terminals 3.4.1 Terminal layout *1 The terminal functions as the terminal FM for the FM type, and as the terminal CA for the CA…
(3) Insert the wires into a socket. Wire removal Pull the wire while pushing the open/close button all the way down firmly with a flathead…
Show all 68 pages
4.4 Control logic (sink/source) change Change the control logic of input signals as necessary. To change the control logic, change the jumper…
5 Safety stop function 3.5.1 Function description The terminals related to the safety stop function are shown below. *1 In the initial status…
5.3 Safety stop function operation *1 At an internal safety circuit failure, the operation panel displays one of the faults shown below. *2 SA is…
4 FAILSAFE OF THE SYSTEM WHICH USES THE INVERTER When a fault is detected by the protective function, the protective function activates and output a…
5 PRECAUTIONS FOR USE OF THE INVERTER The FR-A800 series is a highly reliable product, but incorrect peripheral circuit making or operation/handling…
PRECAUTIONS FOR USE OF THE INVERTER Vector control is available with an encoder-equipped motor. And such an encoder must be directly connected to a…
1 Operation panel (FR-DU08, FR-DU08-01) 6.1.1 Components of the operation panel (FR-DU08, FR-DU08-01) No. Component Name Description Operation mode…
1.2 Basic operation (factory setting) *1 For the details of operation modes, refer to the Instruction Manual. *2 Monitored items can be changed.…
2 Parameter list For simple variable-speed operation of the inverter, the initial values of the parameters may be used as they are. Set the necessary…
Frequency jump 3B 0 to 590Hz, 9999 9999 37 Speed display 0, 1 to 9998 0 41 Up-to-frequency sensitivity 0 to 100% 10% 42 Output frequency detection 0…
Speed control gain (Advanced magnetic flux vector) 0 to 200%, 9999 9999 90 Motor constant (R1) 0 to 50 , 9999 *2 9999 0 to 400m , 9999 *3 91 Motor…
Backlash acceleration stopping time 0 to 360s 0.5s 142 Backlash deceleration stopping frequency 0 to 590Hz 1Hz 143 Backlash deceleration stopping time…
to 239 Multi-speed setting (speeds 8 to 15) 0 to 590Hz, 9999 9999 240 Soft-PWM operation selection 0, 1 1 241 Analog input display unit switchover 0…
Pulse train I/O selection 0, 1, 10, 11, 20, 21, 100 (FM type) 0 0,1 (CA type) 292 Automatic acceleration/ deceleration 0, 1, 3, 5 to 8, 11 0 293…
Orientation selection 0 to 2 0 396 *8 Orientation speed gain (P term) 0 to 1000 60 397 *8 Orientation speed integral time 0 to 20s 0.333s 398 *8…
Second target position upper 4 digits 0 to 9999 0 469 Third target position lower 4 digits 0 470 Third target position upper 4 digits 0 471 Fourth…
USB communication check time interval 0 to 999.8s, 9999 9999 549 Protocol selection 0, 1 0 550 NET mode operation command source selection 0, 1, 9999…
Second brake operation time at stop 0 to 5s 0.3s 648 Second deceleration detection function selection 0, 1 0 650 Second brake opening current…
Second PID action selection 0, 10, 11, 20, 21, 50, 51, 60, 61, 70, 71, 80, 81, 90, 91, 100, 101, 1000, 1001, 1010, 1011, 2000, 2001, 2010, 2011 0 754…
Torque limit level during deceleration 0 to 400%, 9999 9999 818 Easy gain tuning response level setting 1 to 15 2 819 Easy gain tuning selection 0 to…
Speed feed forward filter 0 to 1s 0s 879 Speed feed forward torque limit 0 to 400% 150% 880 Load inertia ratio 0 to 200 times 7 times 881 Speed feed…
C9 (930) *9,*11 Current output bias current 0 to 100% 0% C10 (931) *9,*11 Current output gain signal 0 to 100% 100% C11 (931) *9,*11 Current output…
Analog source selection (1ch) 1 to 3, 5 to 14, 17 to 20, 22 to 24, 32 to 35, 40 to 42, 52 to 54, 61, 62, 64, 67, 87 to 98, 201 to 213, 222 to 227, 230…
Second PID set point/deviation input selection 1 to 5 2 1141 Second PID measured value input selection 1 to 5 3 1142 Second PID unit selection 0 to…
Tenth positioning acceleration time 0.01 to 360s 5s 1259 Tenth positioning deceleration time 0.01 to 360s 5s 1260 Tenth positioning dwell time 0 to…
7 TROUBLESHOOTING When a fault occurs in the inverter, the protective function activates, and the PU display automatically changes to one of the fault…
TROUBLESHOOTING 7.1 Reset method of protective function The inverter can be reset by performing any of the following operations. Note that the…
TROUBLESHOOTING *1 Not available for FR-A842 (Separated converter type) *2 Not available for FR-A846 (IP55 compatible models) *3 Available for FR-A846…
8 SPECIFICATIONS 8.1 Rating 8.1.1 FR-A820 (200V class) *1 The applicable motor capacity indicated is the maximum capacity applicable for use of the…
SPECIFICATIONS 8.1.2 FR-A840 (400V class) *1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi…
SPECIFICATIONS 8.1.3 FR-A842 (400V class) *1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi…
A APPENDIX A.1 Instructions for Compliance with the EU Directives The EU Directives are issued to standardize different national regulations of the EU…
A.1.2 Low Voltage Directive We have self-confirmed our inverters as products compliant to the Low Voltage Directive (conforming standard EN 61800-5-1)…
Wiring protection For installation Class T, Class J, or Class CC fuse or UL 489 Molded Case Circuit Breaker (MCCB) according to the local directives…
A.2 Instructions for UL and cUL (Conforming standard UL 508C, CSA C22.2 No.14) A.2.1 General precautions A.2.2 Installation FR-A820/A840/A842…
A.2.5 Motor overload protection When using the electronic thermal relay function as motor overload protection, set the rated motor current to Pr. 9…
Mitsubishi Electric Europe B.V. / FA - European Business Group / Gothaer Straße 8 / D-40880 Ratingen / Germany / Tel.: +49(0)2102-4860 / Fax…
More documents for Laptops Sharp PC-A800
Sharp PC-A800 Operations Instructions
(80 pages)
Sharp PC-A800 User Manual
(4 pages)
Questions about Sharp PC-A800
No questions about this manual yet. Ask the first one.
Related products and manuals for Laptops Sharp PC-A800
- Laptops Sharp PC-9080 Specifications
(114 pages) - Laptops Sharp PC-9800T Specifications
(125 pages) - Laptops Sharp PC-A800 User Manual
(4 pages) - Laptops Sharp PC-AV18 Technical Information
(68 pages) - Laptops Sharp PC-AV18 User Manual

(160 pages) - Laptops Sharp PC-A820 Specifications

(33 pages) - Laptops Sharp PC-A290 Specifications
(82 pages) - Laptops Sharp PC-9300 Technical Information
(68 pages) - Laptops Sharp PC-AR10 Specifications
(107 pages) - Laptops Sharp PC-A500 Specifications
(89 pages) - Laptops Sharp PC-MR70 Specifications
(93 pages) - Laptops Sharp PC-A820 Specifications
(97 pages) - Laptops Sharp PC-A820 Specifications

(53 pages) - Laptops Sharp EL-6560 Specifications
(160 pages) - Laptops Sharp PC-W100T Installation Manual
(48 pages) - Laptops Sharp Actius PC-RD20 Specifications
(120 pages) - Laptops Sharp PC-MM1 User Manual
(123 pages) - Laptops Sharp Actius PC-RD20 Service Manual

(72 pages) - Laptops Sharp PC-A800 Operations Instructions
(80 pages) - Laptops Sharp PC-MC20 Instruction Manual
(46 pages)
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68