I-31
378-845-7 378-846-7
5.2
(W.D.)
ø44
ø32
ø40
89.9
95
(Parfocal distance)
5
4.8
ø42
1.3
(W.D.)
ø44
ø32
ø40
93.7
95
(Parfocal distance)
5
4.7
ø42
37.5 (W.D.)
ø34
ø24.6
ø25
57.5
95
(Parfocal distance)
5
0.4
ø32.2
30.5 (W.D.)
ø34
ø24.6
ø25.2
64.5
95
(Parfocal distance)
5
1
ø32.2
20 (W.D.)
ø34
ø24.4
ø24.8
75
95
(Parfocal distance)
5
0.6
ø32.2
17 (W.D.)
ø34
ø24.4
ø25
78
95
(Parfocal distance)
5
0.4
ø32.2
12 (W.D.)
ø34
ø24.6
ø25
83
95
(Parfocal distance)
5
0.5
ø32.2
378-822-5 378-824-5
378-823-5 378-825-5
378-826-5
378-817-4
378-809-5 378-818-4
378-819-4
15(W.D.)
ø34
ø24.4
ø25
80
95
(Parfocal distance)
5
2.6
ø32.2
17(W.D.)
ø34
ø24
ø25
78
95
(Parfocal distance)
5
1.6
ø32.2
11(W.D.)
ø34
ø23.4
ø24.4
84
95
(Parfocal distance)
5
1.7
ø32.2
ø34
64.5
95
(Parfocal distance)
5
30.5(W.D.)
0.5
ø25.2
ø32.2
BD Plan Apo HR for Bright/Dark Field Observation
Order No. Mag. N.A. W.D. f R D.F. View field 1 View field 2 Mass
378-845-7 50X 0.75 5.2mm 4mm 0.4μm 0.49μm ø0.48mm 0.10x0.13mm 530g
378-846-7 100X 0.90 1.3mm 2mm 0.3μm 0.34μm ø0.24mm 0.05x0.06mm 545g
Note:
These objectives offer extra-high resolving power.
Near-infrared Radiation Corrected
M Plan Apo NIR for Bright Field Observation
Order No. Mag. N.A. W.D. f R D.F. View field 1 View field 2 Mass
378-822-5 5X 0.14 37.5mm 40mm 2.0μm 14.0μm ø4.8mm 0.96x1.28mm 220g
378-823-5 10X 0.26 30.5mm 20mm 1.1μm 4.1μm ø2.4mm 0.48x0.64mm 250g
378-824-5 20X 0.40 20.0mm 10mm 0.7μm 1.7μm ø1.2mm 0.24x0.32mm 300g
378-825-5 50X 0.42 17.0mm 4mm 0.7μm 1.6μm ø0.48mm 0.10x0.13mm 315g
378-826-5 100X 0.50 12.0mm 2mm 0.6μm 1.1μm ø0.24mm 0.05x0.06mm 335g
378-863-5* 50X 0.65 10mm 4mm 0.4μm 0.7μm ø0.48mm 0.10x0.13mm 450g
378-864-5* 100X 0.70 10mm 2mm 0.4μm 0.6μm ø0.24mm 0.05x0.06mm 450g
* High Resolution (HR objectives)
Note:
These objectives are designed so that a workpiece's image
can be focused within the focal depth even when the
wavelength used is changed anywhere from the visible
range (l = 480nm) up to near-infrared range (l = 1800nm).
Therefore the M Plan NIR Series are suitable for laser repair.
However, when the wavelength used exceeds 1100nm, the
focusing position may slightly deviate from that in the visible
range due to changes in glass dispersion and refractive index.
Near-ultraviolet Radiation Corrected
M Plan Apo NUV for Bright Field Observation
Order No. Mag. N.A. W.D. f R D.F. View field 1 View field 2 -
378-809-5 10X 0.28 30.5mm 20mm 1μm 3.5μm ø2.4mm 0.48x0.64mm 255g
378-817-6 20X 0.40 17.0mm 10mm 0.7μm 1.7μm ø1.2mm 0.24x0.32mm 340g
378-818-6 50X 0.42 15.0mm 4mm 0.7μm 1.6μm ø0.48mm 0.10x0.13mm 350g
378-819-4 100X 0.50 11.0mm 2mm 0.6μm 1.1μm ø0.24mm 0.05x0.06mm 380g
378-888-6* 50X 0.65 10.00mm 4mm 0.42μm 0.65μm ø0.48mm 0.10x0.13mm 500g
*High resolution (HR objective)
Note:
These objectives are designed so that a workpiece's image
can be focused within the focal depth even when the
wavelength used is changed anywhere from the visible
range (l = 620nm) to the near-ultraviolet range (l = 355nm).
Therefore The M Plan NUV Series are suitable for laser repair
using a high frequency laser beam.
DIMENSIONS
Unit: mm
DIMENSIONS
Unit: mm
DIMENSIONS
Unit: mm
Mag.: Magnification
N.A.: Numerical aperture
W.D.: Working distance
f: Focal distance
R: Resolving power
D.F.: Focal depth
View field 1: Field of view when using ø24mm eyepiece
View field 2: Field of view when using 1/2” CCD camera
10
ø39
ø27.6
ø28
85
95
5
0.3
ø37
M Plan Apo NIR HR 50
×
/
100
×
378-863-5
378-864-5
378-888-6
378-824-5
378-863-5
378-864-5
378-818-4
378-817-4
Comments to this Manuals