14
LC-10A3U
SUPPLEMENT
No
No Power (Power LED indicator still in red)
Go to the adjustment process mode.
Move the cursor to ERROR NO RESET
and click on it (to reset to zero).
Turn off the power.
Is the power turned on again?
1
+B-ADJ 160
MODEL A2U
INCH SIZE 10
TIMER 1
SYSTEM AUTO
NTSC PWM FREQ OCO
PAL PWM FREQ OBD
CLOSED CAPTION OFF
V-CHIP OFF
TV GAIN OFF
ERROR NO RESET 5
Check the back light lamp, D753, Q754, D757 and
their peripheral parts as well as pin (42) of IC2001.
Note:
This model is equipped with the lamp error detection function
that detects the current flowing into the fluorescent lamp and
protects the backlight lamp drive circuit.
If a lamp error is detected, the microprocessor interrupts the
unit and the ERROR NO RESET setting will go up.
When the ERROR NO RESET setting has reached "5", the
microprocessor turns and keeps off the unit's power. To
resume the power, take the above procedure to clear the
ERROR NO RESET setting.