Page view 18
I
XG-XV1
E/A
Replacing the
LCDs
With the top cabinet removed
(1) Remove three screws off the output shield.
(2) Disconnect the LCD flat cable from the output PWB connector.
(3) Remove the lock screws
b
and
“c”.
Detach the R/B adjusting plate or the
G
adjusting
plate
together
with
the
LCD panel.
(4) Separate the LCD panel from the adjusting plate.
(5) Mount a new LCD panel in the reverse order of the above steps
(l),
(2),
(3) and (4).
*
Readjust the convergence and focus. Note that the
G
LCD panel needs no convergence adjustment and has
a small adjustment range in the
Z
direction.
TOP VIEW
FRONT
7
Lock screws
c
G
adjusting plate
\
G-LCD
\
=EI
Itd?
//
G-LCD
SIDE VIEW
(
3
) Lock screws
7
R*B
adjusting plate
ROB-LCD
R-B-LCD
panel
mounting screws
VIEW
mounting screws
Page view 18