Checking the power unit
There is no voltage output at
CN708
Which output voltage line fails?
Is AC voltage(90~264V)applied
across the CN701 connector?
Is AC voltage(90~264V)applied
across the CN706 connector?
Is the fuse F701 open?
Is the resistor R702 open?
Is the Bimetal SW open
Replace Inlet unit.
Check the Output PWB unit
Check the T703, IC703, IC705,
IC706 and their peripheral circuits.
Check the CN701 or AC cord.
Is the resistor R775 open?
Replace Power unit.
Replace the R775.
Replace the F701.
Replace the R702.
Push the red button of the bimetal.