Sharp SJ-43N-BE Service Manual Page 9

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 8
9
SJ-P43N/43N
SJ-P47N/47N
LIST OF ELECTRICAL PARTS
ITEMS TYPE NAME RATING SPECIFICATIONS
Thermostat MM1-8149 125V 6A (At normal notch)
250V 3A ON/OFF : -20 / -25˚C
Defrost thermostat S101 250V 8A Open/Close : 8 / 1˚C
Thermo. fuse SF70E 250V 10A Working temp. : 70˚C
Fan motor 3R00121A 220-240V 50/60Hz Working with ø100 fan
Defrost heater MM6-4264 220-240V 378 140W at 230V
Door switch DSD-5 250V 0.25A 4 terminals push-button type
Damper thermostat MM1-6173 Open/Close : 5 / 0˚C
Defrost timer ND1004M2 220-240V Integration type
50/60Hz Cycle time : 10h44m/8h57m(50/60Hz)
Delay time : 4m20s/3m37s(50/60Hz)
Lamp socket 250V 1A E-12(Hard plastic body type)
Lamp 240V 15W E-12
Compressor FL1568SD 220-240V/50Hz Cooling capacity : 188W (50Hz)
Main coil : 13.3
Aux. coil : 25.6
(at 25˚C)
Starting relay PETOSAT 22 300V
3 terminals
Overload relay(Protector) 1.8C36A1 Open/ Close : 130/60˚C
Ionizer-K
(Plasmacluster unit)
FTRN-A014CBKZ DC12V 3.5kV p-p
(Only for SJ-P43N,P47N)
Common
Main coil
Aux. coil
Page view 8