Sharp FO-90A User Manual Page 11

  • Download
  • Add to my manuals
  • Print
  • Page
    / 11
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 10
pb^`lk
GLOBAL PRODUCTION
Callejon Terrazos #8, Local 2-C, Las Brisas 1ra. Seccion,
Tijuana, B.C., Mexico C.P. 22610.
TEL: +52 (664) 626-2726
FAX: +52 (664) 686-8922
Website: www.seaconglobal.com
Dial from U.S.A. TEL: +1 (619) 308-7901
TOLL FREE: (888) 562-7072
FAX: +1 (619) 308-7900
pb^`lk
1700 Gillespie Way,
El Cajon, California 92020, USA.
TEL: +1 (619) 562-7071
FAX: +1 (619) 562-9706
Website: www.seaconworldwide.com
pb^`lk
US GULF AREA SALES OFFICE
14511 Old Katy Road, Suite 300,
Houston, Texas 77079, USA.
TEL: +1 (281) 599-3509
FAX: +1 (281) 599-3517
Website: www.seaconworldwide.com
pb^`lk
ENCAPSULATING AND MOLDING FACILITY
1718 Fry Road, Suite 250,
Houston, Texas 77084, USA.
TEL: +1 (281) 394-0216
Website: www.seaconworldwide.com
pb^`lk
US EAST COAST SALES OFFICE
15 Gray Lane, Suite 108, Hopkinton Industrial Park,
Ashaway, Rhode Island 02804, USA.
TEL: +1 (401) 637-4952
FAX: +1 (401) 637-4953
Website: www.seaconworldwide.com
pb^`lk
ADVANCED PRODUCTS, LLC
1321 Nelius Road, P.O. Box 767,
Bellville, Texas 77418, USA.
TEL: +1 (979) 865-8846
FAX: +1 (979) 865-8859
Website: www.seacon-ap.com
pb^`lk
BRAZIL
Rua Conde de Bonfim 120 sala 212, Tijuca,
Rio de Janeiro, Brazil, CEP: 20520-053.
TEL #1: +55 (21) 3592-0920
TEL #2: +55 (21) 3594-0920
CELL: +55 (21) 98849-3336
Website: www.seaconworldwide.com
pb^`lk
(europe) LTD
Seacon House, Hewett Road, Gapton Hall Industrial Estate,
Great Yarmouth, Norfolk, NR31 0RB, UK.
TEL: +44 (0) 1493-652733
FAX: +44 (0) 1493-652840
Website: www.seaconeurope.com
pb^`lk
PHOENIX
15 Gray Lane, Suite 108, Hopkinton Industrial Park,
Ashaway, Rhode Island 02804, USA.
TEL: +1 (401) 637-4952
FAX: +1 (401) 637-4953
Website: www.seaconphoenix.com
HANDLING PROCEDURES AND SPECIAL CAPABILITIES
All reasonable efforts have been taken to ensure that the information contained herein is accurate at
the date of publication, but no representation or warranty as to the accuracy or completeness of such
information is intended or to be implied by its inclusion herein. Any and all representations and
warranties pertaining to the information and products referred to herein shall be set forth in pb^`lk
standard sales order form. In addition, pb^`lk reserves the right to make changes to the contents
hereof without notice, therefore it is suggested that at the time of inquiry, the appropriate sales office
or factory be contacted directly for verification of published specifications and products availability.
© 2014 pb^`lk
ALL RIGHTS RESERVED
Even though these procedures appear simple, only qualified technicians
should perform the installation and maintenance. Connectors are designed
for installation on one atmosphere vessels. Contact pb^`lk for recommen-
dations if using compensated vessels.
INSTALLATION PROCEDURES
Torque values referenced in this literature assume installation into dry metal
threads. For other applications, please contact pb^`lk for recommenda-
tions. All connectors should be clean and free from moisture prior to mating.
Bulkhead Connector Receptacle (BCR): Lubricate the BCR o-ring with an
appropriate silicone grease before installing. This lubrication should be
applied to form an adequate film. Excessive lubrication is detrimental to the
operation of the connector.
Cable Connector Plug (CCP): Lubricate the o-ring and sealing areas using
an appropriate silicone grease (the engaging nut can be moved back to pro-
vide access to these seals). The retaining ring will need to be moved to the
alternate groove provided for this purpose. After the seals are replaced, the
nut and ring will need to be put back in their working positions.
CARE AND MAINTENANCE
After mating, the `pJjp connector requires no maintenance. It is recom-
mended that upon disconnecting or retrieving a system that utilizes the `pJ
jpseries, the `pJjp connectors should be dried, cleaned, regreased and
remated prior to deploying or storage. It is recommended that when not
mated, the BCR or CCP should be protected with a Sealing Cap Receptacle
(SCR) or Sealing Cap Plug (SCP).
CABLE AND CONTINUITY PRESERVATION
Avoid sharp bends in cables. Cables subjected to vibration and exposed to
seawater drag should be adequately clamped to prevent fatigue and possi-
ble failure.
FIBER OPTIC MAINTENANCE INSTRUCTIONS
· All Fiber Optic connectors should be covered with a protective cap while
not in use.
· Fiber handling is important when dealing with Fiber Optic connectors.
· Do not exceed the bend radius of any given fiber.
· The face of a Fiber Optic ferrule should not come into contact with any
abrasive material.
· Cleaning of a Fiber Optic ferrule should be done with Isopropyl Alcohol
and a soft foam swab or applicant.
· “Clean” ferrule protectors should be placed over the ferrule when not in
use.
· Connectors should be stored in a rigid container to prevent damage to
fiber.
· Fiber should be stored in a vertical manner, preferably on a spool to
maintain the proper bend radius.
· Airborne contaminants on the face of a ferrule can decrease the
performance of a Fiber Optic connection.
· Lube the mating seals as needed to provide proper fit, form and function.
· Do not look directly into Fiber Optic connectors.
REV VIII