34 Rockwell Automation Publication PFLEX-IN020C-EN-P - July 2013
PowerFlex 700S and 700H Frames 10...14 IP00, NEMA/UL Open Power Structures
PowerFlex 700H Control
Connections
Note: For PowerFlex 700S control connections, see PowerFlex 700S Control
Connections on page 40
.
The PowerFlex 700H control uses fiber optic connections and 24V DC supplied
from the ASIC circuit board, which is located on the power structure. Frame 12
and 14 drives contain two ASIC boards and two ASIC Feedback boards that
supply these connections.
Refer to the figures 19
, 20 and 21 for the location of the ASIC board(s).
Figure 19 - Frames 10 and 12 ASIC Board Locations
IMPORTANT
It may be necessary to disconnect the control connections during drive
installation and then re-connect according to the instructions in 700H Control
Connections on page 36
.
DANGERDANGER
DC BUS CONDUCTORS AND CAPACITORS
OPERATE AT HIGH VOLTAGE. REMOVE POWER
AND WAIT 5 MINUTES BEFORE SERVICING
DANGERDANGER
DC BUS CONDUCTORS AND CAPACITORS
OPERATE AT HIGH VOLTAGE. REMOVE POWER
AND WAIT 5 MINUTES BEFORE SERVICING
ASIC Board Assembly
Frames 10 and 12
Power Structure #2
Frame 12 Only