system.check.
‘,‘.
:
Although a CD is inserted and the cover is closed, “NO
DISC” is displayed.
r-
Press the OPEN/CLOSE switch
(SWl)
without inserting a
disc, and try starting the playback operation.
c
1.
Does the pickup move to the PICKUP-IN Switch (SW4)
oosition
?
I-
No
Sled motor
(MZ).
Figure
42-1
2. Does the focus (lens) move up and down
?
(Waveform drawing Figure 42-l)
No
t-4
Check the focus peripheral circuit.
I
I
No
3. Is the laser lit
?
)
Check the laser diode driver
Cl
peripheral circuit.
4. Is the turntable rotating
?
When a disc is loaded, start playback operation.
No
)
Spindle motor (Ml).
1. Is focus servo activated
?
(Waveform drawing Figure 42-2)
No
)
Pins 7-12, 79 and 80 on
ICl
Check the laser diode driver
Cl
peripheral circuit.
I
Yes
No
)
Is the disc rotating
?
No
---)
Check the spin system.
I
I
I
I
,
If the disc is spinning and a HF waveform is generated,
DRF will go H.
3. Is the HF waveform normal
?
(Waveform drawing
If
the level is not normal.
Figure 42-3)
Figure 42-2
Figure 42-3