Sharp XE-A207W Service Manual Page 41

  • Download
  • Add to my manuals
  • Print
  • Page
    / 54
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 40
XE-A207/A217/A307 SRV MODE
– 39 –
2-3. MEMORY INITIAL
1) Select “3 MEMORY INITIAL from the SETTING menu to display the
items list.
2) When this job is selected, YES/NO dialogue is appeared. If “YES” is
selected, MEMORY INITIAL is executed.
MEMORY INITIAL clears the following data.
• GT
• Z counter
• Totalizer (Quantity/Amount, Daily/Term)
• CC-No.
Transaction No. (for Sweden, NORMAL/TRAINING)
• EJ
• EJ VIEW
MEMORY INITIAL prints the following data on journal (EJ).
2-4. SSR
1) Select “4 SSR” from the SETTING menu to display the items list.
2) Select a pertinent dept. code from the SSR list.
SSR INPUT
1) Select “1 SSR INPUT” from the SSR menu to display the items list.
2) Input the SSR data.
STEP#1: SSR No.(1 to 127)
STEP#2 to 4000: SSR data(0 to 127)
• [ 2 ][ 4 ] key can be used for re-entering SSR No. and SSR data.
[TL/NS] key cannot be entered until 10 steps are entered.
Header, title and programming content are printed (recorded) on jour-
nal (EJ).
SSR EDIT
This job can be executed after SSR that includes over 10 steps was
entered.
This job can be executed when all SSR are invalid by “SSR ALL
CLEAR” job or “SSR IND.CLEAR” job.
1) Select “2 SSR EDIT” from the SSR menu to display the items list.
STEP#1: SSR No.(1 to 127)
STEP#2 to 4000: SSR data(0 to 127)
• [ 2 ][ 4 ] key can be used for re-entering SSR No. and SSR data.
[TL/NS] key cannot be entered until 10 steps are entered.
Header, title and programming content are printed (recorded) on jour-
nal (EJ).