2 - 49
YASKAWA PC• 1
Available PC
* Other kinds of MEMOBUS unit can be connected.
1 6
19200bps
Even
8 bit RTU
1
CRC (fixed)
Baud Rate
Parity
Transmission
Code
Data Length
Stop Bit 1
Port
Error Check
Item Setting of PC
19200bps
Even
1
Comm. Parameter of ZM-
**
0 (fixed)
Port Delay Timer
1
PC Type Setting of ZM-
**
Contents
GL60 series, PROGIC-8
Type 1
Same as before
GL120/130 series
Type 2
Standard binary mode
Select [TYPE 1] or [TYPE 2] from [Trans. Mode] in [Comm. Parameter] of the ZM-71SE.
Communication Setting
GL60 series
Memobus port
on a CPU module
PORT2 on a CPU unit
GL120,
GL130 series
PROGIC-8
JAMSC-IF60
JAMSC-IF61
JAMSC-IF611
PC Link Unit
Wiring Diagram
(refer to P2-50, 51)
RS-232C [Wiring Diagram 1]
RS-422 [Wiring Diagram 3]
RS-232C [Wiring Diagram 1]
RS-422 [Wiring Diagram 4]
RS-232C [Wiring Diagram 2]
JAMSC
-120NOM27100
JAMSC-IF612
JAMSC-IF613
ZM-71SE
Model Setting
Memobus
The recommended communication parameter setting of both PC and ZM-
**
is as follows:
2 YASKAWA PC • 1