[7] G: THERMAL CUT-OUT TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the thermal cut-out. Then using an ohmmeter, make a continuity test across the two
terminals as described in the below.
Table: Thermal Cut-out Test
Parts Name
Temperature of “ON” condition
(closed circuit).
Temperature of “OFF” condition
(open circuit).
Indication of ohmmeter (When
room temperature is approx. 20°C.)
Thermal cut-out 125°C This is not resetable type. Above 125°C Closed circuit
Thermal cut-out 145°C Below 115°C. Above 145°C Closed circuit
If incorrect readings are obtained, replace the thermal cut-out.
An open circuit thermal cut-out (MG) indicates that the magnetron has overheated, this may be due to resistricted ventilation, cooling
fan failure.
An open circuit thermal cut-out (OVEN) indicates that the oven cavity has overheated, this may be due to no load operation, or exces
-
sive heat / fire inside the oven.
CARRY OUT
4R CHECKS.
[8] H: MOTOR WINDING TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the motor. Using an ohmmeter, check the resistance between the two terminals as described in the table
below.
Table: Resistance of Motor
Motors Resistance
Fan motor Approximately 399Ω
Turntable motor
Approximately 14.7kΩ
Convection fan motor Approximately 288kΩ
If incorrect readings are obtained, replace the motor.
CARRY OUT
4R CHECKS.
[9] I: NOISE FILTER TEST
CARRY OUT 3D CHECKS.
Disconnect the leads from the terminals of the noise filter.
Using an ohmmeter, check between the terminals as described in the following table.
MEASURING POINT INDICATION OF OHMMETER
Between N and L Approximately 680kΩ
Between terminal N and WHITE Short circuit
Between terminal L and RED
Short circuit
If incorrect readings are obtained, replace the noise filter unit.
CARRY OUT 4R CHECKS.
[10] J: BLOWN FUSE 20A
CARRY OUT 3D CHECKS.
If the fuse 20A is blown, there is a shorts or grounds in electrical parts or wire harness. Check them and replace the defective parts or
repair the wire harness.
CARRY OUT
4R CHECKS.
CAUTION: Only replace fuse with the correct value replacement.
[11] K: BLOWN FUSE F8A
CARRY OUT 3D CHECKS.
1. If the fuse F8A is blown when the door is opened, check the monitored latch switch and monitor switch.
2. If the fuse F8A is blown by incorrect door switching replace the defective switch(es) and the noise filter (fuse F8A).
3. If the fuse F8A is blown, there could be shorts in the asymmetric rectifier or there is a ground in wire harness. A short in the
asymmetric rectifier may be occurred due to short or ground in H.V. rectifier, magnetron, high voltage transformer or H.V. wire.
Check them and replace the defective parts or repair the wire harness.
CARRY OUT
4R CHECKS.
F8A
20A
WHT
RED
R1
R2
N
Cx
Cy
L
L
L
L (min) Cx ± 20% Cy ± 20% R1 R2
1.0mH 0.22 uF 4700pF 10 M 680k
Service_R-890SLM.indd 17 4/25/09 10:55:18 AM